Modular Matrix Switcher 32x32
32
Example: “12B12,13,15.” to transfer signal from the input 12 to output 12,13,15.
9
、
Inquire the input channel to the output channel [x]: Status[x].
Example: Send “Status3.” to inquire the input channel to the output 3.
10
、
Inquire the input channel to the output channels one by one: Status.
Example: “Status.” to inquire the input channel to the output channels one by one.
11
、
Save the present operation to the preset command [Y]: Save[Y].
Example: “Save7.” to save the present operation to the preset command No.7.
12
、
Recall the preset command [Y]: Recall[Y].
Example: “Recall5.” to recall the preset command No.5.
13
、
Clear the preset command [Y]: Clear[Y].
Example: “Clear5.” to clear the preset command No.5.
14
、
EDID management command:. EDIDM[X]B[Y].
Example: “EDIDM5B3.” to enable input 3 to learn the EDID data of output 5.
15
、
Command for signal cards: USER/[Y]/[X]*****.
Example: “USER/I/7:0623%;” to set the input 7 to support YPbPr signal, the card is
plugged in the second input slot of the matrix.
4.4. TCP/IP Control (Optional)
4.4.1. Control Modes
TCP/IP default settings: IP is 192.168.0.178, Gateway is 192.168.0.1, and Serial
Port is 4001. IP & Gateway can be changed as you need, Serial Port cannot be
changed.
l
Controlled by Single PC
Connect a computer to the TCP/IP port of the Modular Matrix Switcher 32x32, and
set its network segment to the same as the default IP of the Modular Matrix Switcher
32x32 (192.168.0.178).