7. EDID Management
The Extended Display Identification Data (EDID) is used by the source device to match
its video resolution with that of the connected display. The source device obtains its
EDID from the first connected display as default setting. However, since displays with
different capabilities can be connected to the splitter, the EDID DIP switch can be used
to set the EDID to a fixed value.
l
The EDID switch on front panel:
Switch Status
Description
L.RES
The splitter reads EDID from all connected displays, and then
the source device will automatically obtain the EDID which
contain the lowest resolution.
PRESET
Switch to the preset EDID, and the preset EDID can be set
via the 4-pin EDID switch on rear panel. The factory default is
720p.
H.RES
The splitter reads EDID from all connected displays, and then
the source device will automatically obtain the EDID which
contain the highest resolution.