INSTRUCTIONS MANUAL
pag.14 - 12/11/2015
THE MACHINE
BASIC COMPONENTS
Refer to Figures 5, 6, 7 and 8.
a) Control consoles
b) Taps
h) Wheels
l) High/Low Pressure threaded connectors
m) Used oil tank
n) New oil container
bi) Oil scale
d) Bottle
e) Drying filters
o) Electronic scale
r) Heating resistance
ps) Serial port
i) Main switch
j) Socket for electrical supply plug
k) Fuse
f) Vacuum pump
u) USB port
z) tracer container
v) purge valve
CONTROLS AND CONTROL SYSTEM
Refer to Figure 9.
A1) High pressure gauge
A2) Low pressure gauge
A3) Keyboard
A4) Bottle pressure gauge
A5) LCD: 4 lines, 20 characters
A6) Printer
FUNCTION SELECTOR KEYBOARD
STOP: Press to interrupt the operation being performed in the case of the principal functions:
recovery - oil discharge - vacuum/oil reintegration - charging). Press START to resume
operation from the point of interruption. Pressing STOP during an alarm state, error state, or
end-of-operation silences the audible alarm.
RESET: Press to interrupt the operation being performed. The procedure may be restarted
from the beginning.
ENTER: Press to confirm the procedure or operation flashing on the LCD.
: Press to move downward from one procedure or operation to another within a menu.
: Press to move upward from one procedure or operation to another within a menu.
START: Press to launch the procedure or operation shown on the display.
ALARMS
HIGH PRESSURE ALARM: Beeper advise when the pressure of the fluid in the circuit reaches
20 bar. The recovery operation is automatically interrupted.
FULL BOTTLE ALARM: Beeper advise when the bottle is filled to more than 80% of maximum
capacity; that is, 18 kg. The RECOVERY operation is automatically interrupted (to cancel this
alarm, charge one or more A/C systems before recovering any more refrigerant).
EMPTY BOTTLE ALARM: Beeper advise when the quantity of refrigerant fluid contained in the
bottle is low.
SERVICE ALARM: Beeper advise whenever the total recovered refrigerant amounts to 100 kg.
To deactivate the alarm, replace the filters and the vacuum pump oil. A code for canceling the
alarm is supplied with the spare filters.
Summary of Contents for WAC 2200
Page 2: ...INSTRUCTIONS MANUAL pag 2 12 11 2015...
Page 5: ...INSTRUCTIONS MANUAL pag 5 12 11 2015 DELETION 40 CONTRAST 41...
Page 86: ...MANUALE D USO pag 86 12 11 2015 CANCELLAZIONE 123 CONTRASTO 124...
Page 210: ...Fig 1 Fig 2 Fig 3 CE LABEL...
Page 211: ...Fig 4 1...
Page 212: ...Fig 5 a i j k...
Page 213: ...Fig 6 ps v u bi...
Page 214: ...Fig 7 h b l f...
Page 215: ...z d n m r Fig 8 o...
Page 216: ...Fig 9 A5 A4 A1 A2 A3 A6...
Page 217: ...4 MAX min 3 2 1 Fig 10...
Page 218: ...5 Fig 11...
Page 219: ...bt Fig 12...
Page 220: ...Fig 14 F F i g 1 2 Fig 15 Fig 16 Fig 17...
Page 221: ...1 Fig 18 2...