INSTRUCTIONS MANUAL
-7-
3 – AUTOMATIC (machine w/ manual valves and graphic b/n screen)
From ASSISTED PROCEDURE, scroll down with the DOWN ARROW , select “A/C System
Flushing”,:
press ENTER , the following screen will be displayed:
press ENTER , the following screen will be displayed:
Use DOWN ARROW and UP ARROW to select the desired amount, then press ENTER
to confirm. NOTE: selectable amount (steps of 500 g) between 1000 and 7500 grams
press START , the following screen will be displayed:
A/C SYSTEM FLUSHING
Open high and low
Pressure taps, then
Press F1 to continue
F2 to Exit
A/C SYSTEM FLUSHING
Connect the flushing
kit as explained in
manual
Press F1 to continue
F2 to Exit
A/C SYSTEM FLUSHING
Flushing refrigerant
Total amount
xxxx g
Press F4
A/C SYSTEM FLUSHING
Vacuum
xx min
Press F4
ASSISTED PROCEDURE
Purification
Bottle Filling
Air Purge
A/C System Flushing
Dynamic Diagnosis
Static Diagnosis