2- R1234YF MANUAL VALVES
Refer to Fig.2, operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the yellow hose 150mm (f), to the check valve (c)
with orientation as showed in the figure and to the black hose 150mm (e).
3) Connect the other terminal of the Black hose 150mm (e) to the outlet (a3) of the 6,5l
accumulator (a)
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a)
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b)
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the yellow hose 150mm (f), to the check valve (c) with
orientation as showed in the figure and to the black hose 150mm (e).
8) Connect the other terminal of the black hose 150mm (e) to the Clip connection (b).
3- R134A AUTOMATIC VALVES
Refer to Fig.3,operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the Black hose 150mm (g);
3) Connect the other terminal of the Black hose 150mm (g) to the outlet (a3) of the 6,5l
accumulator (a);
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a);
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b);
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the Black hose 150mm (g);
8) Connect the other terminal of the Black hose 150mm (g) to the Clip connection (b).
4- R1234YF AUTOMATIC VALVES
Refer to Fig.3, operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the yellow hose 150mm (f);
3) Connect the other terminal of the yellow hose 150mm (f) to the outlet (a3) of the 6,5l
accumulator (a)
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a)
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b)
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the yellow hose 150mm (f);
8) Connect the other terminal of the yellow hose 150mm (f) to the Clip connection (b).