Planning 

• 

Plan your system together with your entrepreneur/reseller. Apply for a permit at your local city hall or environment- or 
construction department before ordering.  

• 

How many toilets will you be needing? If another toilet will be installed in the future, we recommend you plan ahead.  

Have in mind… 

• 

EcoVac is a real vacuum system that transports the waste to the septic tank in a few seconds. The system is a VOD 
(Vacuum on demand) and is only on for a few seconds at each flush. 

• 

To install a vacuum toilet is not like other toilet installations. The waste-pipes are 50 mm Ø and the system is sensitive to 
long distances and sharp turns. Read more on page 8! Maximum distance between WC - Septic tank = 30m. Maximum 
distance between Septic tank - turbine unit BASE = 20m, If the BASE unit is installed outside the tank. 

• 

The turbine (BASE) is exposed to a harsh environment and will be worn out after a few years. You can replace the 
turbine yourself or have it replaced at Wostman or a reseller for a low cost. 

Planering 

• 

Planera toalettsystemet och avloppet tillsammans med din entreprenör/ återförsäljare. Ansök om tillstånd hos din 
kommun, leta under ”miljö och hälsa” eller ”Vatten och Avlopp”.  

• 

Hur många toaletter kommer att behövas? Ska en ytterligare toalett installeras närmsta tiden kan det vara bra att planera 
för detta redan nu. 

Att tänka på… 

• 

EcoVac är ett riktigt vakuumsystem som transporterar avfallet hela vägen till tanken på några sekunder. Systemet är ett 
VOD (Vacuum on demand) och är endast igång några sekunder vid varje spolning, annars är systemet trycklöst och 
vilande. 

• 

Att installera en vakuumtoalett är inte som andra rörinstallationer. Avloppsrören till tanken är 50 mm Ø och ledningarna 
är känsliga för långa avstånd och skarpa böjar. Läs mer på sida 8! Max avstånd mellan WC - Tank = 30m. Max avstånd 
mellan Tank - motorenhet BASE = 20m, om BASE-enheten monteras utanför tanken.  

• 

Motorn in vakuumenheten (BASE) sitter i en känslig miljö och kommer därför att förbrukas efter en viss tid, ca 4 - 6 år. 
Motorn går att byta ut själv utan några verktyg men kan även bytas ut hos Wostman eller återförsäljare till 
självkostnadspris.

Summary of Contents for EcoVac BASE

Page 1: ...Wostman This manual should be saved EcoVac Manual...

Page 2: ...ise frost damage can emerge Forbidden objects in the WC Napkins paper towels feminine hygiene products cotton balls etc should not be flushed down the WC Only toilet paper with shorts fibers should be...

Page 3: ...atten annars kan frostskador uppst F rbjudna objekt i WCn Servetter hush llspapper mensskydd bomullstussar osv f r inte spolas ned i toaletten Endast toalettpapper med korta fibrer f r anv ndas Fullst...

Page 4: ...cerad utanf r tanken 1 wc to tank above ground Turbine placed outside the tank 1 wc till tank ovan jord Motor placerad utanf r tanken 2 wc to BOSS 2 composting system Turbines placed in the basement 2...

Page 5: ...Vac Manual Page of 5 17 450 mm 580 mm 395 mm Stainless hose Rostfri flexislang 50 mm outlet 50 mm utlopp Front Back Junction box Kopplingsdosa Solenoid valve Magnetventil Stainless flush button Rostfr...

Page 6: ...self or have it replaced at Wostman or a reseller for a low cost Planering Planera toalettsystemet och avloppet tillsammans med din entrepren r terf rs ljare Ans k om tillst nd hos din kommun leta und...

Page 7: ...ktriska uttag For 1 EcoVac WC only F r 1 EcoVac WC endast Creates vacuum in the septic tank Bildar vakuum i den slutna tanken Septic tank that can handle vacuum is necessary Tank som klarar undertryck...

Page 8: ...nstalled with any type of septic tank Kan installeras med olika sorters tankar The tower engine room and the septic tank should be ventilated Tornet maskinrummet och tanken ska ventileras EXTEND unit...

Page 9: ...flush in case of a power breakdown Lutning p r ren rekommenderas f r att kunna spola vid str mavbrott Long smooth turns should be used for the best vacuum performance L nga j mna sv ngar ska anv ndas...

Page 10: ...str ng hela v gen runt nedre kanten f rutom bakre kanten Ta bort verfl digt silicone The very last step of the installation is connection the water Test flush the WC before first usage Det allra sista...

Page 11: ...d the pipes from the wc Skruva fast bollkorgen med bollen p undersidan av den medf ljande plattan Placera plattan med bollkorgen ner t i h let i montageplattan och t ta med monteringslim Anslut r ren...

Page 12: ...paren och vidare till ventilationsr ret via ett Y r r enligt bilden ovan F st ljudd mparen mot v ggen med hj lp av de vita st lskenorna Installing the BASE unit on top of the tank Place the ball insid...

Page 13: ...aced The BASE unit can be mounted in a different place or on the wall right above the EXTEND unit F lj stegen p sidan f r installation av BASE enheten Den enda skillnaden r att BASE enheten ska inte p...

Page 14: ...urbine BASE is often placed in a moist locked place under ground and do not have constant power Connect the signal cable to the WC before you connect the control unit to any power One extra single pha...

Page 15: ...nom att h lla inne denna knapp i 3 sek TEST Test flush Testspolning Flush to clean the bowl Adjust the time depending on water pressure until cleaning satisfaction Spolning f r att reng ra sk len Just...

Page 16: ...three program alternatives Tryck p knappen MODE Displayen b r nu visa tre bokst ver som r en f rkortning av ett program Tryck p knappen f r att v xla mellan de tre program alternativen Fat If you have...

Page 17: ...of the septic tank 83 85 av totala volymen av beh llaren Ex 3000L tank 2500x 83 85 of the total volume of the septic tank 83 85 av totala volymen av beh llaren Ex 3000L tank 2500x Ex BOSS 2 200x When...