Electrical scheme / 

Elschema

Power central / 

Elcentral

Control unit 1   

Styrenhet 1

Junction box /  

Kopplingsdosa

Signal cable  12V to WC / 

Signalkabel 12V till WC

Outlet on the tank for frost guard and 

heating cable. Not three-phase! 

Vägguttag i tanktornet för frostvakt och 

värmekabel. Ej tre-fas!

Septic tank 

(Or other container / 

Eller annan uppsamlingsenhet) 

Recommendations / 

Rekommendationer:

 

The control unit should be placed in a dry and accessible place. Preferably inside the house, by the power central. (It 
should not be put next to the vacuum turbine (BASE) or the vacuum unit (EXTEND). It should be easy to find and you 
should de able to hear the alarm signal. 

Tank alarm should be installed on the septic tank. This should also be taken into consideration during wiring. 

Wire the control unit without RCD (Residual current device) since the vacuum turbine (BASE) is often placed in a moist, 
locked place under ground and do not have constant power. 

Connect the signal cable to the WC before you connect the control unit to any power. 

One extra single phase cable should be installed at this point from the power central to the tank. This cable should be 
installed with constant power for the frost guard and heat cable. (OBS. don’t use three phase cable).

Styrenheten ska placeras på ett torrt och lättillgängligt ställe. Helst inne i huset vid elcentralen (den ska inte sitta vid 
motorenheten (BASE). Man ska enkelt kunna hitta den och höra om larmet ljuder från styrenheten. 

Nivålarm på tanken ska installeras. Detta bör även planeras in för eldragning. 

Anslut helst styrenheten till uttag utan jordfelsbrytare eftersom motorenheten (BASE) sitter i ett fuktigt, låst utrymme 
under mark och inte har konstant ström. 

Anslut signalkabeln till WC innan styrenheten kopplas på med ström. 

En extra 1-faskabel ska läggas samtidigt från husets elcentral ut samma väg till tanken, denna med fast ström till frostvakt 
och värmekabel. OBS. ej 3-faskabel!

Summary of Contents for EcoVac BASE

Page 1: ...Wostman This manual should be saved EcoVac Manual...

Page 2: ...ise frost damage can emerge Forbidden objects in the WC Napkins paper towels feminine hygiene products cotton balls etc should not be flushed down the WC Only toilet paper with shorts fibers should be...

Page 3: ...atten annars kan frostskador uppst F rbjudna objekt i WCn Servetter hush llspapper mensskydd bomullstussar osv f r inte spolas ned i toaletten Endast toalettpapper med korta fibrer f r anv ndas Fullst...

Page 4: ...cerad utanf r tanken 1 wc to tank above ground Turbine placed outside the tank 1 wc till tank ovan jord Motor placerad utanf r tanken 2 wc to BOSS 2 composting system Turbines placed in the basement 2...

Page 5: ...Vac Manual Page of 5 17 450 mm 580 mm 395 mm Stainless hose Rostfri flexislang 50 mm outlet 50 mm utlopp Front Back Junction box Kopplingsdosa Solenoid valve Magnetventil Stainless flush button Rostfr...

Page 6: ...self or have it replaced at Wostman or a reseller for a low cost Planering Planera toalettsystemet och avloppet tillsammans med din entrepren r terf rs ljare Ans k om tillst nd hos din kommun leta und...

Page 7: ...ktriska uttag For 1 EcoVac WC only F r 1 EcoVac WC endast Creates vacuum in the septic tank Bildar vakuum i den slutna tanken Septic tank that can handle vacuum is necessary Tank som klarar undertryck...

Page 8: ...nstalled with any type of septic tank Kan installeras med olika sorters tankar The tower engine room and the septic tank should be ventilated Tornet maskinrummet och tanken ska ventileras EXTEND unit...

Page 9: ...flush in case of a power breakdown Lutning p r ren rekommenderas f r att kunna spola vid str mavbrott Long smooth turns should be used for the best vacuum performance L nga j mna sv ngar ska anv ndas...

Page 10: ...str ng hela v gen runt nedre kanten f rutom bakre kanten Ta bort verfl digt silicone The very last step of the installation is connection the water Test flush the WC before first usage Det allra sista...

Page 11: ...d the pipes from the wc Skruva fast bollkorgen med bollen p undersidan av den medf ljande plattan Placera plattan med bollkorgen ner t i h let i montageplattan och t ta med monteringslim Anslut r ren...

Page 12: ...paren och vidare till ventilationsr ret via ett Y r r enligt bilden ovan F st ljudd mparen mot v ggen med hj lp av de vita st lskenorna Installing the BASE unit on top of the tank Place the ball insid...

Page 13: ...aced The BASE unit can be mounted in a different place or on the wall right above the EXTEND unit F lj stegen p sidan f r installation av BASE enheten Den enda skillnaden r att BASE enheten ska inte p...

Page 14: ...urbine BASE is often placed in a moist locked place under ground and do not have constant power Connect the signal cable to the WC before you connect the control unit to any power One extra single pha...

Page 15: ...nom att h lla inne denna knapp i 3 sek TEST Test flush Testspolning Flush to clean the bowl Adjust the time depending on water pressure until cleaning satisfaction Spolning f r att reng ra sk len Just...

Page 16: ...three program alternatives Tryck p knappen MODE Displayen b r nu visa tre bokst ver som r en f rkortning av ett program Tryck p knappen f r att v xla mellan de tre program alternativen Fat If you have...

Page 17: ...of the septic tank 83 85 av totala volymen av beh llaren Ex 3000L tank 2500x 83 85 of the total volume of the septic tank 83 85 av totala volymen av beh llaren Ex 3000L tank 2500x Ex BOSS 2 200x When...

Reviews: