WorldWide Electric Motor WDFC Quick Start Guide
This guide and all referenced information is intended for qualified personnel only.
For additional information, please consult the WDFC User Manual
1-800-808-2131
6
Press Program/ Enter to Continue
This menu is to program input your restart functions.
Please refer to the manual for further instructions.
Press Program/ Enter to Continue. This menu is to input the number of restarts.
Please refer to the manual for further instructions
.
Input if you would like to resume running when the power is restored
.
Press Program/Enter to Continue. This menu is to set the Speed Search.
Please refer to the manual for further instructions
.
EzStart N STP 0.0Hz
PRT08 RST Restart
D:
C:
EzStart N STP 0.0Hz
PRT09 Retry Number
0 ~ 10
D:0
C:0
EzStart N STP 0.0Hz
COM96 PowerOn Resume
0
1
No
Yes
DC
EzStart N STP 0.0Hz
CON71 Speed Search
D:
C:
Input your command source. If you would like to use the keypad
to start and stop select 0 Keypad.
If you would like to use a switch to Start/Stop, select the correct input.
Input your Reference source.
1. Move your arrow keys and input your desired speed (Hz).
2.Select the Hand On the Keypad and monitor your Speed (Hz).
3.Select the Off Button to stop operation.
*VERIFY MOTOR ROTATION*
DRV06 Cmd Source
1
Fx/Rx-1 DC
2
Fx/Rx-2
0
Keypad
EzStart N STP 0.0Hz
DRV07 Freq Ref Src
EzStart N STP 0.0Hz
0
Keypad-1 DC
1
Keypad-2
2
V1
Frequency Set Point
Frequency Set
Hand On
Left Arrow
Right Arrow
Press Program / Enter to continue
This menu is to program input the restart functions.
Please refer to the manual for further instructions.
(WorldDrive Flex Control - VFD - The WDFC: Operation and Instructional
Manual)
wwec.co/WDFC-Manual
Press Program / Enter to continue. This menu will input the number of
auto restarts. Please refer to the manual for further instructions.
Select Yes if operation is to resume running when the power is restored.
Press Program / Enter to continue. This menu is to set the Speed Search.
Please refer to the manual for further instructions.
Input your reference source.
1. Position the “left arrow” / “right arrow” keys and input your desired speed (Hz).
2. Select the ”Hand” on the Keypad and monitor your Speed (Hz).
3. Select the [OFF] Button to stop operation.
Verify motor rotation:
1. On the keypad, set DRV07 to 1 (keypad)
2. On the keypad, set a frequency reference value
3. If the dive is in OFF mode, press the [AUTO] key to start / bump the drive in
forward (Fx) direction and press the [OFF] key
WDFC Quick Start Guide
EzStart Steps