3.25.1.
Principle of re-transmissions / acknowledgements functioning
As long as its acknowledgement has not been received, the notification will be re-transmitted at a rate of one
sending every <d> seconds, a maximum of <n> times; where <d> and <n> are the fields respectively <Ack Timeout>
(1)
and <Max Retries>
(2)
.
If acknowledgement does not arrive following <n> attempts, the notification is “frozen”, that-is-to-say, it is put on
standby until a new notification of the same type occurs. It can also be manually “unfrozen” using the “Replay
Traps” button
(3)
.
It is important to note that non transmitted notifications are not lost. They are kept to be re-transmitted when
conditions permit it once again. When a new notification occurs the “frozen” notification is re-activated, and a
cycle of sending attempts starts up again.
3.25.2.
Events leading to sending of SNMP notification
o
EquipmentOn
(identifier: 161): it is equivalent to ColdStart except that it can be acknowledged and
re-transmitted if necessary. Transmitted just after ColdStart.
o
HeartBeat (identifier: 168): notification sent at regular intervals to give equipment sign of life.
Configurable on page “SNMP agent”.
o
ConfigurationChanged (identifier: 169): transmitted when system configuration is modified.
o
EquipmentFault (identifier: 1610): transmitted on application critical error or system breakdown.
o
Phone Alert Enable (identifier: 2000): transmitted when the phone alert function is enabled.
Specific applicative alarms (ScriptEasy)
o
ScriptEasy Info alarm (identifier: 1610000): ScriptEasy INFO type alert (event having no distinct
beginning or end)
o
ScriptEasy On/Off alarm (identifier: 1610001): ScriptEasy ON/OFF type alarm (event marking
beginning or end of a state)
o
Manager alarm (identifier: 1610002): ScriptEasy alarm compatible with the Broadcast Manager.
Remember to click the ‘Update’ button in each section to lock in any changes.