4
Adjusting Blower Speed
Accent Lighting
These models include adjustable blower speed
control for (3) levels of operation – Hi, Med and
Low. The switch is located on the printed circuit
board inside the dryer as shown in Fig. 1 below.
Note: The factory setting for the
blower speed control is “Hi”.
To adjust blower speed:
1. Disconnect the power source.
2. Use the security hex key supplied to turn
the cover mounting screws
clockwise
to
remove the cover from the dryer.
3. Locate the switch on the printed circuit
board inside the dryer as shown in Fig. 1
below, and adjust blower speed as desired.
(Note: When Med or Low speed is selected,
LED 3 on the printed circuit board will be lit).
Reassemble the dryer cover using the
security hex key supplied to turn the cover
mounting screws
counter-clockwise
and tighten until snug. Do not over tighten.
4. Reconnect the power source.
The dryer’s accent lighting can be adjusted to operate continuously or only when the dryer is
activated for drying hands )default factory setting(. Most energy efficient operation is with the default
factory setting. To change the lighting mode, press the light mode switch shown in Fig. 2 below.
LED's
DIAGNOSTIC
SPEED CONTROL
SWITCH
Figure 2
Figure 1
Summary of Contents for VERDEdri Q A2 Series
Page 2: ...This Page Intentionally Left Blank...
Page 45: ...44 3 Med Hi Low 1 Hi 1 2 3 1 LED 3 4 2 2 LED s DIAGNOSTIC SPEED CONTROL SWITCH 1 LED...
Page 49: ...48 LED 4 PCB LED 4 46 18 LED LED 3 LED 4 277 208 277 208 4 LED 3 120 277 208...
Page 51: ...This Page Intentionally Left Blank...
Page 52: ......