background image

2

   Description

World Dryer recess mounted, ADA compliant warm air hand dryer, powered by a high speed universal motor, delivering 2300 Watts of 

drying power. This hand dryer runs on 115 Volts AC, 208/220-240 Volts AC, or 277 volts AC electrical supply, depending on model. 

Automatic and push-button models are represented in this product group. This appliance is intended for use in hand drying, 

contributing to 

hygienic and cost effective hand sanitation. This hand dryer may be used in commercial, industrial, office and public 

facility environments.

   General Specifications 

   Electrical Specifications

(cULus Listed, E19860, CE TUV-GS)

  General Safety Information

      

DANGER

 

• Always disconnect the power source before servicing or installing the hand dryer.

       

DANGER

• This hand dryer must be properly grounded (Earthed) for safe operation. An identified ground connection point is supplied on the

hand dryer’s wall base.

• We recommend GFCI protection in wet or damp locations or as required by local code.

       

WARNING

• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed.

• Connect the hand dryer to the nearest suitable distribution panel.

• To limit a voltage drop, and insure efficient operation, use wire gauge as required by local or National Electrical Code.

• Do not connect to a branch circuit with CB or fuse protection over 20 Amps. This is in compliance with The National Electrical Code.

• All automatic model hand dryers must have a dedicated 20 Amp circuit as required by Underwriters Laboratories, Inc. (UL).

• Route all field wiring away from any moving parts within the hand dryer.

       

CAUTION

  

Improper mounting could result in personal injury or property damage.

1. Remove all packing material. Recycling is recommended.

2. Carefully remove the hand dryer from the shipping carton, using care not to drop the appliance.

3. Inspect carefully for any damage that may have occurred during transit. Check for any loose, missing or damaged parts. If the

hand dryer is damaged, promptly inform the shipper or dealer where you purchased it.

Basic Models Nozzle

Drying Cycle

Dimensions (WxDxH)

Weight

Cover Material

DXRA

Fixed

Automatic

13.1” x 13.8” x 4”   

333 mm x 351 mm x 102 mm

26.5 lbs / 12 kgs

Stainless Steel

XRA

Fixed

Automatic

13.1” x 13.8” x 4”   

333 mm x 351 mm x 102 mm

35 lbs / 15.9 kgs

Cast Iron

RA

Fixed*

30 Seconds

13.1” x 13.8” x 4”   

333 mm x 351 mm x 102 mm

35 lbs / 15.9 kgs

Cast Iron

Failure to disconnect the power source before installation or servicing can 

result in serious injury or death from electric shock. 

Failure to properly ground this unit could result in severe electrical shock 

and/or death. 

Risk of fire, personal injury or property damage are possible if local codes, 

NEC codes or safety recommendations are not followed.

Models

Type

Electrical Input

Amperage

Watts

(D) XRA5

Automatic

115 VAC, 60 Hz

20

2300

RA5

Push-button

115 VAC, 60 Hz

20

2300

(D) XRA54

Automatic

208-230 VAC, 60 Hz

10

2300

RA54

Push-button

208-230 VAC, 60 Hz

10

2300

(D) XRA548

Automatic

220-240 VAC, 50 Hz

10

2300

RA548

Push-button

220-240 VAC, 50 Hz

10

2300

(D) XRA57

Automatic

277 VAC, 60 Hz

8.5

2300

RA57

Push-button

277 VAC, 60 Hz

8.5

2300

(*) Rotating Nozzle Option

Unpacking

       

WARNING

 

Cancer and Reproductive Harm - www.p65warnings.ca.gov

Summary of Contents for DXRA Series

Page 1: ...cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqu descrito Prot jase usted mismo y a los dem s observando toda la informaci n de seguridad No seguir las ins...

Page 2: ...ers Laboratories Inc UL Route all field wiring away from any moving parts within the hand dryer CAUTION Improper mounting could result in personal injury or property damage 1 Remove all packing materi...

Page 3: ...avoiding switched lighting circuits or other circuits where equipment may be switched on off 9 Provide a minimum length of 24 61cm of wire in the wall box to allow easy connection to the dryer termin...

Page 4: ...nd Dryers Parts List For Repair Parts visit www WorldDryer com Please provide following information Model number Serial number Part description and number shown in parts list 2 3 8 6 4 5 17 20 19 21 1...

Page 5: ...6 006565 1 13 Inlet Grill Cast Iron Push button with Mtg Hardware RA All 194 3K 1 r13 Inlet Grill Cast Iron Automatic with Mtg Hardware XRA All 194 3XRAK 1 14 Tamper Proof Cover Screw Cast Iron Covers...

Page 6: ...nstructions 8 Replace cover Place cover squarely over base and push flush to wall Insert 2 cover mounting screws and tighten until snug Do not over tighten Wiring Diagram Wiring Diagram Model RA5 Wiri...

Page 7: ...7 Wiring Diagram Model D XRA57 Wiring Diagram Model D XRA54 Wiring Diagram Model D XRA5 Wiring Diagram Model D XRA548 Wiring Diagram Model RA57...

Page 8: ...lieved to be defective within limited warranty first write or call dealer from whom the product was purchased Dealer will give additional directions If unable to resolve satisfactorily write to World...

Page 9: ...cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqu descrito Prot jase usted mismo y a los dem s observando toda la informaci n de seguridad No seguir las ins...

Page 10: ...20 amperios para satisfacer los requisitos de Underwriters Laboratories Inc UL Encamine todo el cableado realizado durante la instalaci n lejos de todas las partes m viles dentro del secamanos ATENCI...

Page 11: ...s de luces ni ning n otro circuito al que est n conectados artefactos con interruptor 9 El conductor debe tener al menos 61 cm de longitud en la caja de embutir para facilitar la conexi n de los termi...

Page 12: ...a informaci n sobre repuestos visite www WorldDryer com Por favor proporcione la siguiente informaci n N mero de modelo N mero de serie Descripci n de la pieza y n mero indicados en la lista de partes...

Page 13: ...de entrada fundici n de pulsador con torniller a de montaje RA todos 194 3K 1 r13 Rejilla de entrada fundici n funcionamiento autom tico con torniller a de montaje XRA todos 194 3XRAK 1 14 Tornillo r...

Page 14: ...la pared Inserte dos 2 tornillos de montaje de la cubierta y apri telos hasta que est n ajustados No los apriete demasiado REEMPLAZO DE LAS ESCOBILLAS DEL MOTOR 1 Retire la presilla de resorte de fij...

Page 15: ...7 Diagrama de Cableado Modelo D XRA57 Diagrama de Cableado Modelo D XRA54 Diagrama de Cableado Modelo D XRA5 Diagrama de Cableado Modelo D XRA548 Diagrama de Cableado Modelo RA57...

Page 16: ...de p rdida pasan al comprador en el momento de la entrega del art culo a la compa a de transporte Si el producto se da a durante el transporte debe presentar su reclamo a la compa a transportista 68 8...

Page 17: ...cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqu descrito Prot jase usted mismo y a los dem s observando toda la informaci n de seguridad No seguir las ins...

Page 18: ...re install s sur un circuit d di de 20 amp res Faire passer l ensemble du c blage sur site l cart des pi ces mobiles qui sont l int rieur du s che mains ATTENTION 1 Enlever tous les produits d emballa...

Page 19: ...n Il faut donc galement viter les circuits d clairage interrupteurs ou d autres circuits o les quipements peuvent tre allum s ou teints 9 Laisser d passer une longueur de c ble minimale de 61 cm de la...

Page 20: ...es pi ces Pour les pi ces d tach es consulter www WorldDryer com Fournir les renseignements suivants Num ro de mod le Num ro de s rie Description et num ro de la pi ce figurant sur la liste des pi ces...

Page 21: ...RA tous 194 3K 1 r13 Grille d entr e fonte automatique avec mat riel correspondant XRA tous 194 3XRAK 1 14 Vis de capot inviolable capots en fonte XRA RA tous 100B3 1 14 Vis de capot inviolable capot...

Page 22: ...er le capot en le pla ant droit sur la base et en le poussant contre le mur Ins rer les deux vis de montage du capot et les Sch mas de c blage Sch ma de c blage Mod le RA5 Sch ma de c blage Mod le RA5...

Page 23: ...7 Sch ma de c blage Mod le D XRA548 Sch ma de c blage Mod le D XRA57 Sch ma de c blage Mod le D XRA54 Sch ma de c blage Mod le D XRA5 Sch ma de c blage Mod le RA57...

Page 24: ...ate et le num ro de la facture du concessionnaire ainsi que la nature du d faut constat Le titre et le risque de perte passent l acheteur au moment de la livraison par le transporteur Si le produit a...

Reviews: