background image

Raw Water System

246SF /266SF

RETRACTABLE

SHOWER OUTLET

RAW WATER PUMP W/IN.L1NE

FILTER

ACCESSED

THRU STARBOARD

BATTERY

HATCH

I

SUPPLIED

THRU BAITWELL

PUMP

ANDIOR INTAKE STRAINER

(314"

TUBING)

SEACOCK

(1/4

TURN BALL VALVE)

ACCESSED

THRU STARBOARD

MOTOR WELL INSPECTION

PORT

o

II

r

j'

J

L

r/~\\

lUI/~~\\

16

o

o

Summary of Contents for 226SF

Page 1: ...2 000 OWNER S MANUAL 2000 226SF 246DC 246SF 266SF 266SC Hu IIEPy _...

Page 2: ...ICAL SYSTEM BATTERY INFORMATION WIRING CODE GAUGE TROUBLESHOOTING QUICK REFERENCE INSTRUMENT OPERATION TROUBLESHOOTING WINDLASS WIRING OPERATION MAINTENANCE TRAILER BRAKE REQUIREMENTS A PANEL SWITCH I...

Page 3: ...methods available today This dedicated team makes its contributions in many ways and all have only one thing in mind A safe and pleasurable boating experience for each of our customers that has chosen...

Page 4: ...plain the problem and ask for assistance in resolving the situation The owner is usually in the best position to help you and is concerned with both your overall satisfaction and your future business...

Page 5: ...electronics other components and or the installation of said items that are not previously approved and authorized by the manufacturer 7 Damage which has occurred as a result of the boat being operate...

Page 6: ...d complete a warranty card along with a signed warranty sheet Within the 1st year Within the 2 nd year Within the 3 year Within the 4 h year Within the Sth year After the Sth year SOO OO 400 00 300 00...

Page 7: ...Cabin Hatch 3 yrs 203 458 6200 Perko Bow I Stern Lights 5 yrs 305 621 7525 Rule Industries Bilge Pumps 5 yrs pro rated 978 281 0573 Rule Industries div Danforth Compass 3 yrs 978 281 0573 Scandvik Wa...

Page 8: ...POSITION WHEN BOTH ENGINES ARE RUNNING WARNING LEAKING FUEL IS A FIRE EXPLOSION HAZARD INSPECT FUEL SYSTEM REGULARLY FOR LEAKS CORROSION BUT AT LEAST ANNUALLY Model 266SC Only Bow Area Seating ALL MOD...

Page 9: ...at all times when the boat is being operated There is extreme danger to the passengers should the door be left open during operation as the wind flow could cause it to suddenly close and severely hur...

Page 10: ...damage Avoid the use of any product not specifically designed for use on stainless steel and check to make certain that other nearby surfaces will not be damaged through such use For further informati...

Page 11: ...l all chlorine odor is removed WINTERIZATION LAY UP Refer to the motor manufacturer s manual for storage instructions Drain all fresh and raw water tanks Remove batteries and store in a dry cool area...

Page 12: ...em inside the bilge at the bottom just forward of the bilge pumps not silicone refer to the manufacturer s instructions For tri ducer installations depth temp speed it may be best to purchase a separa...

Page 13: ...otors first center the starboard motor by turning the helm Then open the system ball valve located beneath the inspection port on the dive platform by turning it 90 degrees This will isolate the port...

Page 14: ...MINATED LEADING TO STEERING FAILURE READ INSTRUCTIONS ON TUBE PRIOR TO USE VALVE Quantity Description Part Application 1 Helm Pump 1 7 Tiit Helm All Models 2 O B Cylinders HC 5345 All Models 1 20 Hose...

Page 15: ...ylinder shaft all the way out on fitting 2 side of cylinder _Turn wheel counter clockwise until an air free stream of oil comes forth from bleed fitting 2 then close bleed fitting 2 _ Open bleed fitti...

Page 16: ...Fuel System 246DC EXTERNAL VENT ACCESS PORTS o o o 0 ACCESS PORTS NOTE OPTIONAL FLOSCAN DETAILS NOT SHOWN FUEL TANK FUEL TANK 0 0 00 00 D FUEL FILTERS D 12...

Page 17: ...m 246SF 266SF o OJ EXTERNAL VENT ACCESS PORTS NOT INSTALLED ON 266SC 0 ACCESS PORTS NOTE OPTIONAL FLOSCAN DETAILS NOT SHOWN o oo 0 FUEL TANK o c FUEL FILTERS I FUEL TANK 10110 EXTERNAL VENT FUEL FILL...

Page 18: ...tem 266SC DOO EXTERNAL VENT ACCESS PORTS 0 0 NOT INSTAllED ON 266SC 0 0 FUEL TANK FUEL TANK ACCESS PORTS 101 0 EXTERNAL VENT 0 FUEL Fill rlOOI 11 J FUEL FILTERS NOTE OPTIONAL FlOSCAN r iD DETAilS NOT...

Page 19: ...ER FAUCET o o RAW WATER PUMP W IN L1NE FILTER ACCESSED THRU STARBOARD BATTERY HATCH I SUPPLIED THRU BAITWELL PUMP ANDIOR INTAKE STRAINER 3 4 TUBING SEACOCK 1 4 TURN BALL VALVE ACCESSED THRU STARBOARD...

Page 20: ...R OUTLET RAW WATER PUMP W IN L1NE FILTER ACCESSED THRU STARBOARD BATTERY HATCH I SUPPLIED THRU BAITWELL PUMP ANDIOR INTAKE STRAINER 314 TUBING SEACOCK 1 4 TURN BALL VALVE ACCESSED THRU STARBOARD MOTOR...

Page 21: ...SHOWER OUTLET v o Lll o o RAW WATER PUMP W IN L1NE FILTER ACCESSED THRU STARBOARD BATTERY HATCH SUPPLIED THRU BAITWELL PUMP AND OR INTAKE STRAINER 3 4 TUBING SEACOCK 1 4 TURN BALL VALVE ACCESSED THRU...

Page 22: ...Fresh Water System 246DC 10 GAL SUPPLY TANK FRESHWATER PUMP WI IN LINE FILTER FILL WI INTEGRAL VENT RETRACTABLE SHOWER OUTLET o 18 o...

Page 23: ...Fresh Water System 246SF 266SF FRESHWATER PUMP WI IN L1NE FILTER RETRACTABLE SHOWER OUTLET FILL WI INTEGRAL VENT 20 GAL SUPPLY TANK o o o o 1001 D n J 19 I D...

Page 24: ...FAUCET 35 GAL SUPPLY TANK BELOW LOCKER STORAGE FILL WI INTEGRAL VENT RETRACTABLE SHOWER OUTLET 1 2 1 0 SUPPLY TUBING IN GUNNEL I If I I iI I I C c o o FRESHWATER PUMP W IN L1NE FILTER ACCESSED THRU P...

Page 25: ...igh speed water is rammed into the pick up and pump running or not At 30 mph 48 kph flow is almost double Flows that are faster than 7 minutes for periods of more than 20 minutes can harm or kill the...

Page 26: ...IN 1 1 2 TUBING END OF DAY DRAIN WI REMOTE CONTROL VALVE 3 4 TUBING NOTE L1VEWELL FLOW CONTROL OFF MAX INSTALLED WI END OF DAY DRAIN ON SIDE OF HELM SEAT PORTSIDE 266SC STBRD SIDE 246SF 266SF Livewell...

Page 27: ...running The batteries may therefore discharge completely if the boat is unused over an extended period approx 30 days In such cases use of a maintenance trickle charger is recommended or optionally di...

Page 28: ...inverter s wattage capacity In battery amp hour capacity This should provide 1 hour of full inverter capacity However be sure to add additional 12 volt amp draws Bilge Pump 500 gph Bilge Pump 1000 gph...

Page 29: ...GREY 14 5A BREAKER PANEL GREY WI ANCHOR LIGHT WHITE STRIPE 14 5A BREAKER PANEL BROWN WI BAITWELL PUMP YELLOW STRIPE 14 5ABREAKER PANEL ATTACHED TO BAITWELL LIGHT BLUE 14 BAITWELL SW BROWNW FRESH WATER...

Page 30: ...auge Slicking Inoperative Reading Incorrectly NO LIGHT Bad Gauge 12 Volt or YES Gnd Fault Clean or Check Fuses Tighten and Connections Connections Clamp was too Tight NO NO Snug it up Recheck Bad Gaug...

Page 31: ...the lens to return the pointer to zero Either of these methods can be used with switch on back of the tach in the correct position to return to normal operation Lens Fogging Most marine instruments ha...

Page 32: ...r applied 2 No signal supplied or 3 tach damaged by electrical transients caused by disconnecting the battery with the engine running 1 Check to see if power is applied to tach by switching the instru...

Page 33: ...own source of S and the other lead to the ground terminal of the gauge If lamp lights or voltage is indicated on the voltmeter while touching the ground terminal of the gauge the ground connection to...

Page 34: ...nual for trouble shooting procedure b If test voltmeter indicates correct voltage typically 14 volts with engine running and at least 12 volts with no accessories on and engine off see outboard motor...

Page 35: ...Kabeldurcnmessers hang abvonGesamtkebelange AtBtC O E Von Batterie zur Ankerwinde und von Ankerwinde zur BaUerle Installation La choix d epaisseur de clhle depero de1alongueurIOOl iJ c3b1e AtBtC O E R...

Page 36: ...stent with both wind and current making sure that you are not driving over the rode as the windlass retrieves it 3 During anchor retrieval the rode may begin to pile up beneath the windlass motor Obst...

Page 37: ...Jersey 3 000 Colorado 3 000 New Mexico 3 000 Conneclicul 3 000 New York 3 000 Delaware 4 000 North Carolina 1 000 Florida 3 000 North Dakola ALL Georgia 2 500 Ohio 2 000 Hawaii 1 500 Oklahoma 3 000 I...

Page 38: ...H ALL THE GAUGES AND WIRING 09 0029 HONDA VERSION IS WITH NO GAUGES THE 2 HOLE PLUGS AND THE DIMMER INSTALLED AND NO WIRING 09 0030 HINE FABRICATION NOTES TLANTIC MARINE PRODUCTS INC All 011 4 ARE 010...

Page 39: ...OARD SIDE CUSTOMER TO HOOK UP THIS WIRE 6 GRAY DROP OFF LEAD SEE ASSY DWG 16 BLACK DROP OFF LEAO SEE ASSY DWG 16 PURPLE DROP OFF LEAD SEE ASSY DWG LEAD WIRES ARE SAME FOR PORT BUT SEPERATE DROPOFF DO...

Page 40: ...HA MERC 09 0031 HOLE PLUG e o I HOLE PLUG c D E F SMALL 1 2 DIA HOLE PLUG 2643 1 REO D LARGE GAUGE HOLE PLUG 2482 1 REO D PANEL TECHNO STYLE NAF034 1 REO D F G G H 8 7 6_ 5 MACHINE FABRICATION NOTES A...

Page 41: ...HARD RED 1 LENS WCMSOO WITH MASTER POWER SCREENED ON IT 12 VOLT POWER POINT MARINCO 12VRC OEM FUSEBLOCKS HELLA WATER TIGHT STYLE 8 WAY WITH COVER 62940 1 PER ASSEMBLY 6 WAY WITH COVER 62938 1 PER ASS...

Page 42: ...RES 1 9 ALL OTHERS ARE REMOVED FROM PLUG SIDE ONLY ALL WIRES GET ULTRAS WIRES ON MASTER BOX ARE ALL CUT 20 LONG o 6 6 7 7 THIS WIRING DIAGRAM IS FOR THE CABIN MODEL SWITCH PANEL ASSEMBLY 09 0032 8 8 W...

Page 43: ...POWER STUD CUSTOMER TO INSTALL J 10 RED 50 WITH lORING WIRE LABELED POWER STUD D DATA COM Y CABLE E F G o CUSTOMER TO HOOK UP TO DDEe 10 RED 50 WITH 10 RING F G H THIS PANEL IS ASSEMBLED AS SHOWN ABOV...

Page 44: ...TER I Ie MASTER SW POD SLAVE SW POD o I 50 00054 50 00078 10 LABELS ARE APPLIED TO EACH WINDOW EACH LABEL WILL BE CENTERED AND ABLE TO READ THRU WINDOW ALL LABELS ARE PEEL AND STICK E I IE F G F G H 8...

Page 45: ...30PSI OP1022jXU03600 2 REO O 10 RED MAIN LEAD TO 0 POWER STUD 48 lORING 7 SLAVE SW POD 50 00080 I 4ASTER SW POD 50 00077 ASSEMBLY PARTS 8 BG 88 8 8 PANEL TECHNO S1YlE NAf OJ5 1 REO C CARUNG CONTUft II...

Page 46: ...J 3 2 0 n CD O O r O O u CD 0 0 CDC 0 O O 0 0 N 5 0 r l L OJ 3 0 BSr u f OJ r O O 0 0 CD wO wO 0 0 51 f 1 f to IO O 2 l 0...

Page 47: ...WITH COVER 62940 1 PER ASSEUBLY WAY WITH COVER 62936 1 PER ASSEMBLY FUSES AAE ATC MO STYlE ICNlTION PROTECTID SAMP ATC5 9 PER ASSOIBLY 10N lP ATelO 1 PER ASSOIBlY 15AYP AlelS 1 PER ASSEJ lBlY rusrSlO...

Page 48: ...We 1 o o 0 1 IO o o Q We 1 o o 0 1 0 IO 0 0 0 0 0 3 r o o 3 5 lflr 0 lflO 0 0 0 wO wo 1 0 O O 6 lfll to lflLfl 2Lfl...

Page 49: ...RE REMOVED FROM PLUG SIDE ONLY ALL WIRES GET ULTRAS WIRES ON MASTER BOX ARE ALL CUT 24 LONG 6 7 8 WIRING NOTES ALL WIRING FOR THE DDECS IS APPLIED BEFORE SHIPPING ALL LOOSE WIRES ARE TO BE TY WRAPPED...

Page 50: ...00 B c lACHINE fABRICAnON NOTES AU DIMS ARE t 01O ANGLES ARE 1 UNLESS NOTED OTHERWISE FlNISHED EDGES ARE INDICATED BY FlNISH MARK V PERIMETER EDGES ARE TO BE nNISHED BREAK All SHARP EDGES AND CORNERS...

Page 51: ...LGE I Ie MASTER SW POD SLAVE SW POD D I 50 00077 50 00080 ID LABELS ARE APPLIED TO EACH WINDOW EACH LABEL WILL BE CENTERED AND ABLE TO READ THRU WINDOW ALL LABELS ARE PEEL AND STICK E I IE F G F G H 8...

Page 52: ...E ASSY DWG 15 PURPLE DROP OFF LEAD SEE ASSY DWG LEAD WIRES ARE SAME FOR PORT BUT SEPERATE DROPOFF DO NOT MIX THE 2 SIDES I C 16 BLUE TO PORT SIDE GAUGES FOR LIGHTS WIRES INTO PORT FUEL MACHINE FABRICA...

Page 53: ...RAWING FOR WIRING DIAGRAM AND ALSO CUT SHEETS FOR WIRE LENGHTS AND TERMINALS 5 7 8 TOGGLES ARE CARLING CHROME HANDLE STYLE NAV ANC DPDT ON OFF ON 2GMS1 78 HORN PUSHBUTTON RED 186S0 ALL OTHERS SPST OFF...

Page 54: ...INE PRODUCTS INC BY Gl lW HKBY GuuWORLD CLASS CATAMARAN H I T 1 or x 246 DC INST ISW WIRING ATE DRAWN VISI 4 2000 NTS 09 0034 0 2 Il l GAUGES FINAL WIRING ASSEMBLY 09 0034 MACHINE FABRICATION NOTES AU...

Page 55: ...ITCHES C1131 35 20 BLACK 9 BREAKERS ARE PUSH TO RESET S1YLE 5AMP 1680 217 050 97 5 10AMP 1680 217 100 97 3 15AMP 1680 217 150 97 1 20AMP 1680 217 200 97 1 BOOTS FOR CIRCUIT BREAKERS CLEAR C1221 24 4 C...

Page 56: ...SEMBLY 09 0035 16 BLACK MASTER POWER D LNEWn L 101 Rrn C C Prr L 10 IRED NAVlANe SW DETAIL 16 GA GRY 16GA RED Jl lHPER IE I 1 101 E I I 1 10 IRED RAW WATER r 6 RED I IF I __ LJ 101 I 0 IRED ACCESSORY...

Page 57: ...F D 16G RED JUMPER TO GAUGES TO GAUGES 16 GA GRY 16 BLUE 16 BLACK MASTER POWER 6 RED I ACCESSORY 101 REO 10 IRED FINAL WIRING ASSEMBLY 09 0036 llACHlNE ok FABRICATION NOTES TLANTIC MARINE PROOUCTS IN...

Page 58: ...C1131 35 20 BLACK 9 BREAKERS ARE PUSH TO RESET STYLE 5AMP 1680 217 050 97 5 10AMP 1680 217 100 97 3 15AMP 1680 217 150 97 1 20AMP 1680 217 200 97 1 BOOTS FOR CIRCUIT BREAKERS CLEAR C1221 24 4 CLEAR 1...