background image

 

 

Precautions in operation 

1.  Electric wiring 

Before starting operation, check the rotational direction. When U (red), V (white), W (black), and earth 

(green) are connected, the pump starts. Checking the rotational direction is as follows. 

1-(1) In case of the inverse rotation, the capacity is only 30% of the forward rotation. 

1-(2) When turning on the switch with lifting the pump in water, a counterclockwise back action is in 

the forward direction. 

 

 

 

 

 

 

Note: In case of the inverse rotation, switch two of three cables (Rec, White, Black).

 

2.  Precautions in electric wiring 

 

Make sure to connect a green earth wire to a polar plate or bar before connecting the cable to 

prevent electric shock. 

 

When it is necessary to be the instantaneous operation to check the rotational direction, never 

test the pump in air. Heat makes the pump may deform and causes the failure. 

 

Install a circuit breaker to prevent unexpected problems. 

Note:  To  prevent  electrical  shock  or  fire,  the  user  is  obligated  to  provide  a  leak  breaker 

according  to  the  industrial  safety  and  Health  Regulation  and  Electric  Equipment  Technical 

Standard. (Japan) 

 

 

 

 

Red 

– U  

  <Cable side> 

 

White 

– V 

 

<Motor cable side> 

 

 

 

 

Black 

– W 

 

 

 

 

 

Green 

– Earth 

 

3.  Voltage during operation 

When  the  voltage  is  low,  the  current  increases.  In  this  case,  the  thermal  protector  works  as  the 

temperature of the stator is raised. The low voltage causes the performance failure. Use the pump 

with the voltage within the specified range. 

Note: The applicable voltage for this pump is within 

±

10

  of the rated voltage. 

4.  Thermal protector (Protection Instrument) 

When  the  temperature  of  the  motor  coil  is  near  burning  temperature  for  electrical  or  mechanical 

causes, the burn protection function works and stops the motor by cutting off the electrical circuit. At 

this time, carefully check the operated cause of the thermal protector, and remove it before resuming 

operation. 

Note:  Make  sure  to  turn  off  the  power  before  check.  The  thermal  protector  automatically 

restart. 

 

Positive rotation 

Inverse rotation 

Summary of Contents for SUBMERSE YD-5002GWN1

Page 1: ...SUBMERSIBLE MAGNET DRIVE PUMP SUBMERSE YD 5002GWN1 INSTRUCTION MANUAL Version 171212...

Page 2: ...te and maintain the pump in accordance with the instruction manual Table of contents Warning 2 Caution 3 Model description Specification 4 Outline dimension 5 Features Precautions in handling Temperat...

Page 3: ...not check or disassemble a pump or motor while the power on It leads to personal injuries from electric shock or getting caught in the rotor Take the multiple safety precaution such as the switch for...

Page 4: ...amaged pump When returning the pump by courier clean up the inside and outside of the pump by water Pack it with a plastic bag after checking no liquid Plastic parts The pump is made of plastic If it...

Page 5: ...tion motor H 1 1kW 1 5HP 3 Maximum 2 Standard Maximum Standard Outline Height lbs Direct 58F Starting current Rated current Rated voltage Pole 200 220V 460V 60Hz Attached cable Thermal protector CFR P...

Page 6: ...ic bearing 6 Motor cover CFR PP 20 Stand bolt HT PVC 7 Impeller CFR PP 21 Strainer PP 8 Impeller magnet Ferrite 22 Sludge fence PP 9 Front bearing PTFE Ceramic 23 Bottom plate PP 10 Rear bearing PTFE...

Page 7: ...tor Precautions in handling 1 Slurry accelerates the bearing worn Especially when the pump is used in a settling tank mount the pump to prevent slurry entering or clear slurry Replacement of the beari...

Page 8: ...onal liquid level is correct the operation error may occur to the air entering by the condition of the liquid level If the impeller is operated in the air the rotating parts may be damaged Example of...

Page 9: ...rom a sealed tank 4 For circulating liquid in a tank 5 For mixing liquid in a tank or an equipment 6 For pumping and transferring liquid in emergencies Sample of use Pumping liquid from a deep tank Pu...

Page 10: ...oblems Note To prevent electrical shock or fire the user is obligated to provide a leak breaker according to the industrial safety and Health Regulation and Electric Equipment Technical Standard Japan...

Page 11: ...board 11 on the motor cover 6 2 Slide the impeller 7 from the edge of the separating board 11 to the center In this case do not to slide the impeller quickly to the center The impeller 7 may be pulled...

Page 12: ...11 Exploded view 6 6...

Page 13: ...ion and liquid surface in a tank Inspect no foreign object in the pump and estimate whether it is overload or not Pour priming water and eliminate all air in the pump Clean the suction pipe Motor over...

Page 14: ...WCUSA This Limited Warranty does not cover a defects or damage resulting from accident misuse abnormal use abnormal conditions improper storage exposure to dirt neglect or unusual physical electrical...

Page 15: ...MP NO OTHER WARRANTIES ORAL OR WRITTEN EXPRESS OR IMPLIED ARE GIVEN OUR LIABILITY IS LIMITED TO THE ACTUAL PURCHASE PRICE YOU PAID TO THE RETAIL SELLER OF THE DEFECTIVE PUMP EXCEPT TO THE EXTENT PROHI...

Page 16: ...of use and the condition The failure parts and the condition Type of liquid name specific gravity temperature any slurry or not Clean the inside of the pump adequately when returning it because if the...

Page 17: ...ya shi Aichi 465 0051 Japan TEL 052 701 1227 FAX 052 701 1250 Tsukuba Factory 6127 5 Onogo machi Joso shi Ibaraki 300 2521 Japan TEL 0297 24 1071 FAX 0297 24 1075 WORCHEMI TAIWAN CO LTD Taichung Taiwa...

Reviews: