8. DIGITAL INPUTS
The device’s S.BUS connector plugs directly into the S.BUS output of these devices, although additional care and
resources might be required in case of male‐male connection.
A setting important to the S.BUS port is the
S.BUS Offset
. Since S.BUS has up to 16 channels, the S.BUS Offset
can be set between 0 to 9. For more details, see Table 8.1.
S.BUS Offset
S.BUS Channel
GIS 320 IO
0
1
1
0
7
7
1
1
‐
1
2
1
1
7
6
9
10
1
9
16
7
Table 8.1: S.BUS Offset example ‐ which S.BUS Channel corresponds to GIS 320 IO
8.1.1 S.BUS through Amimon Connex
S.BUS signal from RC transceiver can be sent through Amimon Connex, so there is no need for the receiver. For
this, you need the Amimon Connex and RC transceiver with TRAINER support.
1. Connect the RC transceiver TRAINER port to Amimon Connex receiver.
2. Connect the Amimon Connex transceiver S.BUS port to GIS 320 S.BUS input.
3. Set up the TRAINER channels in RC transceiver.
This setting was tested with Futaba T148G RC controller (TRAINER setting to 8 CH. mode).
Figure 8.5: Amimon Connex TRAINER cable (left) and S.BUS cable (right).