TROUBLE SHOOTING

Note: If the table does not operate properly upon power-up, a cable connection may not be connected correctly. Two things must be done to  

correct this problem.

Step 1.) First check all cable connections to the power supply. If cables are properly connected they will be locked in place. If you pull back  

on each cable and one comes unplugged, re-insert the cable and push in firmly until it locks. Test by pulling back to be sure the cable is  

properly connected.

Step 2.) Perform the “Restore Factory Settings” procedure. Follow the “Restore Factory Settings” instructions and reset the system.

Note: It’s important to follow the steps precisely as noted or the “Restore Factory Settings” may not restore properly allowing both of the legs of the 

table to operate properly once the connection issue is corrected. Repeat the “Restore Factory Settings” procedure again if necessary
Once you’ve corrected the connection problem and performed the reset the table should operate as normal. Repeat starting with Trouble Shooting 

Step 1 if the table still does not operate properly.
If you still have problems with your table, please contact Workrite Ergonomics at (800) 959-9674 “Press 2 for Technical Support” or contact us at 

[email protected]

With this function, you can reset the Sentinel series switches to their original factory settings.

Caution: Restoring "Factory Settings" will remove height limits. Perform this step only if needed to restore the table 

Height Control

Up

Down

LED indicator light

FACTORY RESET

SENTINEL "SS" STANDARD SWITCH

Step

User input 

1

Disconnect the Table System from 120 V power by removing the power cord plug from the power supply

Note: If your Sentinel Base has more than one power supply, all power cords must be removed in t his step

2.

 

Press and hold the

 

UP

 

UP

 

and DOWN  buttons

3.  While holding the

 

UP

 

and DOWN  buttons, reconnect the 120 V power cord to the power supply

Note: If your Sentinel Base has more than one power supply, all power cords must be reconnected in t his step

4. 

 

UP

 

and DOWN  buttons

5.

 

Press the DOWN  button until the table moves and stops. The "Restore Factory Settings" step is now completed

.

Summary of Contents for Sentinel ST2E-30-48 Series

Page 1: ...t Head Allen Screw Qty 12 K 8 Phillips Pan Head Screw Qty 12 L 12 Phillips Pan Head Screw Qty 24 J M8 1 25P 20 mm Flat Head Allen Screw Qty 4 O4 mm Allen Wrench Qty 1 P5 mm Allen Wrench Qty 1 NP Loop...

Page 2: ...Instructions Only applicable to products having a polarized plug power cord Some products include a polarized plug see Figure A One A C plug blade wider than the other to reduce the risk of electrical...

Page 3: ...h O Attach left motor bracket F and right motor bracket E to sides of the legs A using M6 1 25P 12 mm flat head Allen screws I and tighten securely with the 4 mm Allen wrench O Note The right bracket...

Page 4: ...recommend you mark your drill bit at to prevent drilling too deep Caution Do not drill through the worksurface Install four 4 12 Phillips pan head screws L into the 4 corner locations and tighten sec...

Page 5: ...e Right is on the left when table is upside down Place the switch B as shown and drill deep pilot holes with a 3 32 drill bit Install two 2 glides Q into each foot as shown Measure and mark the switch...

Page 6: ...supply between the leg and the power supply Drill deep pilot holes with the drill bit for each cable spool Attach the power supply to the top using two 2 12 Phillips pan head screws L and tighten secu...

Page 7: ...ation it is to be used Plug the table into a 120 V outlet The Sentinel table will take a few seconds to self initialize You will hear a few beeps and the table will be ready to operate Plug the DMP240...

Page 8: ...e reset the table should operate as normal Repeat starting with Trouble Shooting Step 1 if the table still does not operate properly If you still have problems with your table please contact Workrite...

Page 9: ...While holding the UP and DOWN buttons reconnect the 120 V power cord to the power supply Note If your Sentinel Base has more than one power supply all power cords must be reconnected in this step 4 U...

Reviews: