Attach short motor brackets (G) to the legs (A) with two (2) 

#M6 × 1.0P × 12 mm flat head Allen screws (I) and tighten 

securely with the 4 mm Allen Wrench (O).
Attach left motor bracket (F) and right motor bracket (E) to 

sides of the legs (A) using #M6 × 1.25P × 12 mm flat head 

Allen screws (I) and tighten securely with the 4 mm Allen 

wrench (O). 
Note: The right bracket will be on the left and left bracket 

on the right when upside down

ATTACH BRACKETS TO LEGS

1.1

1.2

1

Hardware at actual size

I

 

M6 × 1.0P × 12 mm Flat Head 

Allen Screw

1.1

1.2

A

G

E

O

I

I

G

I

F

A

I

G

I

I

G

Summary of Contents for Sentinel ST2E-30-48 Series

Page 1: ...t Head Allen Screw Qty 12 K 8 Phillips Pan Head Screw Qty 12 L 12 Phillips Pan Head Screw Qty 24 J M8 1 25P 20 mm Flat Head Allen Screw Qty 4 O4 mm Allen Wrench Qty 1 P5 mm Allen Wrench Qty 1 NP Loop...

Page 2: ...Instructions Only applicable to products having a polarized plug power cord Some products include a polarized plug see Figure A One A C plug blade wider than the other to reduce the risk of electrical...

Page 3: ...h O Attach left motor bracket F and right motor bracket E to sides of the legs A using M6 1 25P 12 mm flat head Allen screws I and tighten securely with the 4 mm Allen wrench O Note The right bracket...

Page 4: ...recommend you mark your drill bit at to prevent drilling too deep Caution Do not drill through the worksurface Install four 4 12 Phillips pan head screws L into the 4 corner locations and tighten sec...

Page 5: ...e Right is on the left when table is upside down Place the switch B as shown and drill deep pilot holes with a 3 32 drill bit Install two 2 glides Q into each foot as shown Measure and mark the switch...

Page 6: ...supply between the leg and the power supply Drill deep pilot holes with the drill bit for each cable spool Attach the power supply to the top using two 2 12 Phillips pan head screws L and tighten secu...

Page 7: ...ation it is to be used Plug the table into a 120 V outlet The Sentinel table will take a few seconds to self initialize You will hear a few beeps and the table will be ready to operate Plug the DMP240...

Page 8: ...e reset the table should operate as normal Repeat starting with Trouble Shooting Step 1 if the table still does not operate properly If you still have problems with your table please contact Workrite...

Page 9: ...While holding the UP and DOWN buttons reconnect the 120 V power cord to the power supply Note If your Sentinel Base has more than one power supply all power cords must be reconnected in this step 4 U...