19
PH: 267.350.2809
10.
If you have stored the
GO-A3-PW
for an extended period of time
and
have
not
followed
the previous steps you will need to lubricate
the inside of the air motor prior to start-up.
11.
To lubricate the air motor, first remove it from the frame. With the
hoses disconnected, spray electrical contact cleaner in both open
ports.
12.
Gently work the pinion shaft back and forth until it moves
smoothly.
13.
After the pinion shaft is shifting smoothly, the motor can be placed
back into the frame, and the hoses can be reconnected.
Failure to drain oil will cause the air motor to stall.