Disassembly of the Unit
3730 E. Southern Avenue, Phoenix, AZ 85040 USA
800-778-8779
Workhorseproducts.com
12
The Photosharp Exposure Unit is specifically engineered to facilitate easy disassembly without the use of
special tools or equipment. Disassembly may be required to allow the Photosharp to pass through narrow
doorways.
1. Unscrew the two screws in the
top panel and remove it.
3. Unscrew the two screws in the
bottom drawer and pull it out.
2. With the top panel detached
the glass can be removed. Push
the glass up from below. Pivot
the glass upward while making
sure the glass does not slide off
the track.
4. Once the drawer is removed,
disconnect the photo cell and the
electrical cord as shown. Rest the
wires on the corner brace where
the receptacle is located until
needed.
5. Disconnect the vacuum line
from the tube that exits the rear of
the PhotoSharp and from the
fitting on the vacuum blanket.
With the bottom drawer removed,
disconnect the vacuum line and
the power cords for the light
source and vacuum pump.
6. Notice the row of bolts along the
lip inside the cabinet. Some bolts are
positioned with bolt heads facing up
and others are positioned with the
nuts facing up. Working from within,
remove only the bolt heads facing
up. The upper cabinet may now be
separated from the drawer cabinet.