Read all safety instructions before operating the WM912 amplifiers .
1.Install equipment as follow condition.

Install at flat place, not bending curved.
Do not install near the water and moisture.
Locate power amplifier away from heat source, such as radiators or other
device that produce heat.
Do not drop objects or spill liquids into the inside of amplifier.

2.Keep in mind the following when connecting amplifier.

Connect the amplifier after reading of O P manuals.
Connect each connection of amplifier exactly, if not, it maybe caused hum,
damage, electric shock in case of misconnecting.
To prevent electric shock, do not open top cover.
Connect the power cord with safety after check of AC power.

Amplifiers should be serviced by qualified service person.

1 CHIME SIGNAL(not included)

INTERNAL SETTING HAVE FOUR TONE CHIME
PERMISSIBLE EXTERNAL CHIME REMOTE AND P.T.T REMOTE

2.MASTER R,L OUTPUT

3.TWO BAND EQ PER OUTPUT

4.SIGNAL INDICATOR PER INPUT

5.PERMISSIBLE PHANTOM MIC FOR ALL INPUT

6.AUTOMATIC PRIORITY FOR MIC 1~3

7.SELECTIVE MIC INPUT OF H.P.F

8.SELECTIVE MASTER OUTPUT PER INPUT SIGNAL

(OUTPUT L, L

R, R)

9.INDEPENDENT LINE INPUT WITH RCA PIN JACK(LINE 6~9)

10.RECORDING OUTPUT

11.LED INDICATOR FOR MASTER-OUTPUT

12.AC 230V/DC 24V

FEATURES:

.

1

2

3

4

5

6

1. CHIME

Pressing chime switch, chime signal will be activated as a pre signal. You can adjust level.

IMPORTANT NOTICE

Priority function will be given only for selected output.

2. INPUT 1 CONTROLS

Adjust level volume so as not to turn on +3 LED under two~three O'clock of master volume
this is control for MIC input level.

OUTPUT SWITCH

This is selector that send signal of input 1 to the master output. When input 1 are activated,
signal of input 4~ input 9 will be closed.

3. INPUT 2,3 CONTROLS

Adjust level volume so as not to turn on +3 LED under two~three O'clock of master volume
this is control for MIC LINE input level.

OUTPUT SWITCH

This is selector that send signal of input 2,3 to the master output. When PRIORITY on and
input 2,3 are activated, signal of input 4~ input9 will be closed.

MODE SWITCH

MIC

It is input mic switch of 300Hz H.P.F that makes sound clearance. When you select

switch, windy sound. Resonance frequency, plosive sound will be removed.
MIC

This is MIC input switch without filter line.

LINE

line input for CD, CASSETTE, TUNER.

IMPORTANT NOTICE

Selecting mode switch

" "(HPF)," "(flat) power will be supplied to input XLR connector for condensor MIC only.
If you connect unbalanced dynamic microphone with them, if may be defaulted and
should be minimized level volume before moving to mode switch for noise down.

When you switch "ON", priority is activated and will closed input 4~9.

PRIORITY 2,3

4.INPUT 4~9 CONTROLS

These make adjustment of MIC/LINE for input 4~9. Adjust output level so as not to turn "ON"
+3 LED under two~three O'clock.

OUTPUT SWITCH

This is selector that send signal of input 4~9 the masteroutput. When input 1~3 signal are
supplied,priority will be activated and close output of input 4~9

MODE SWITCH

MIC

It is input mic switch of 300Hz H.P.F that makes sound clearance. When you select

switch, windy sound.Resonance frequency, plosive sound will be removed.
MIC

This is MIC input switch without filter line.

LINE

line input for CD, CASSETTE, TUNER.

IMPORTANT NOTICE

Selecting mode switch

"

"(HPF),"

"(flat) power will be supplied to input XLR connector for condensor mic only.

If you connect unbalanced dynamic microphone with them, it may be defaulted and should
be minimized level volume before moving to mode switch for noise down.

5.MASTER L,R EQ

This is master volume for all input levels you had better use toward two~three O'clock.
Adjust level 3 LED for proper operation.

EQUALIZER

Adjust low, high if EQ volume according to condition.

6.POWER SWITCH

When switches the POWER switch to "ON" position ,then the power indicator lights ,
indicats the apparatus is o n.When switches the PO WER switch to "OFF"po sition

,Then

F

RONT PANEL CONTROLS

S

AFETY INSTRUCTIONS

the power indicator exindicats the apparatus is off.

3

4

POWER

MODE

MODE

MODE

MODE

MODE

MODE

MODE

MODE

PRIORITY

L

R

LOW

LOW

0

10

0

10

0

10

0

10

SIG

1

1 + 2

2

OUTPUT

LINE

0

10

S I G

1

1+2

2

OUTPUT

LINE

0

10

S I G

1

1 + 2

2

OUTPUT

LINE

0

10

S I G

1

1+2

2

OUTPUT

LINE

0

10

S I G

1

1 + 2

2

OUTPUT

LINE

0

10

S I G

1

1 + 2

2

OUTPUT

LINE

0

10

SIG

1

1+2

2

OUTPUT

LINE

0

10

Summary of Contents for WM 912

Page 1: ...R 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 WM 912 User Instructions Equipson S A www equipson es support equipson es ...

Page 2: ...LECTRICSHOCK DONOT OPEN This symbol wherever it appears alerts you to important operating and maintenance instructions in the accompanying literature Read the manual This symbol wherever it appear alerts you to the presence of uninsulated dangerous voltage inside the enclosure voltage that be sufficient to may constitute a risk of shock The appliance should be situated so that its location or posi...

Page 3: ...ut operating voltage is only for condensor microphone if you connect dynamic microphone balanced by mistake microphone will be out of work also be sure not be insert mic input connector under level volume up speaker systems may get damage due to big noise MIC input 6 9 balanced are only for microphone input When you select MIC input operating voltage is only for condensor microphone if you connect...

Page 4: ...ed MODE SWITCH MIC It is input mic switch of 300Hz H P F that makes sound clearance When you select switch windy sound Resonance frequency plosive sound will be removed MIC This is MIC input switch without filter line LINE line input for CD CASSETTE TUNER IMPORTANT NOTICE Selecting mode switch HPF flat power will be supplied to input XLR connector for condensor MIC only If you connect unbalanced d...

Page 5: ...R 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 0 10 WM 912 Instrucciones de Usuario Equipson S A www equipson es support equipson es ...

Page 6: ...de una instrucción importante de mantenimiento o funcionamiento Lea el manual INSTRUCCIONES DE SEGURIDAD DETALLADAS Todas las instrucciones de seguridad deben ser leidas antes de hacer funcionar la unidad Las instrucciones deberian ser conservadas para futuras referencias Todas los avisos incluidos en las instrucciones de funcionamiento deberían ser tomados en consideración Todas las instrucciones...

Page 7: ...os salidas de grabacion izquierda derecha RCA desbalanceado es convertida en señal estèreo en el circuito interno desde la señal mono El volumen de salida de grabación no puede ser controlado por el master porque el circuito que controla la salida de grabación está antes del control de volumen de master 6 GRABACION 7 SALIDAS L R Estas salidas de master pueden ser seleccionas con el conmutador 8 AL...

Page 8: ...S Ajuste el nivel de volumen sin llegar a encender el LED 3 que seran aprox 2 3 del volumen de master Este es el control de nivel de entrada de micro y linea CONMUTADOR DE SALIDA Este es un selector que envia la señal de la entradas 2 3 a la salida master Cuando la prioridad de estas entradas esta activada la señal de las entrada 4 a 9 está desactivada CONMUTADOR DE MODO MIC Es una entrada de micr...

Reviews: