AC Connector:
An appropriate AC line cord and plug are provided. 220 VAC, 50Hz/60Hz units
have a standard 3-wire, 15-amp grounded connector
Controls
Power:
A front panel switch is used to turn the amplifier on and off.
Level
: A front panel rotary potentiometer for each channel is used to control the output level.
Stereo/Mono:
A three-position back panel switch is used to select Stereo, Bridge-Mono or
Parallel-Mono mode.
Input/Output Data
Input Connector:
Balanced XLR connector and RCA unbalanced.
Input Impedance
: Nominally 20k ohms, balanced; 10 k ohms, unbalanced.
Output Connector:
Two sets of color-coded 5-way binding posts (for banana plugs, spade lugs or
bare wire) .
Output Signal Modes
Stereo:
Balanced, two-channel.
Bridge-Mono:
Balanced, single-channel. Channel 1 inputs are active; Both channel volume
controls are available.
Parallel-Mono:
Balanced, single-channel. Channel 1 inputs are active; Both channel volume
controls are available.
7
User Manual/Manual de Uso WCE 200/400
WCE200
WCE400
Power Handling
8 ohm per Channel
150W
220W
4 ohm per Channel
220W
380W
8 ohm bridged
500W
800W
S/N Ratio
>65dB
>67dB
Slew rate
5V/us
5V/us
Damping factor
300
300
Mode switch
Stereo/Parallel/ Bridge
Stereo/Parallel/ Bridge
Crosstalk
>46dB
>46dB
Power ON delay
7 sec
7 sec
Input Sensitivity
0.7V
0.8V
Frequencie response 20-20KHz
< +/- 0.25dB
< +/- 0.25dB
Input connection
XLR
XLR
Link connection
RCA
RCA
Output connection
Binding post
Binding post
Soft start
yes
yes
Operating Voltage
185-245V
185-245V
Dimension/WxDxH/mm
483x277x44
483x277x89
Net weight
THD
0.05%
0.05%
MODEL
3.7kg
4.5kg
EN