background image

In this mode, the dip-switches 11,12  are flipped to the 

OFF

 and 10 to 

ON

. Flip the 

dip-switch 1~3

 to set the intensity of 

Red

 LEDs, 

dip-switch

Green

 LEDs and 

dip-switch 7~9

 to set the intensity of B

lue

 LEDs. Please refer to the following table for further information.

Red

(SW1~3)

Green

(SW4~6)

Blue

(SW7~9)

Intensity

001

57%

101

71%

011

86%

111

100%

001

101

011

111

001

101

011

111

Red

1 2

Green

Blue

3 4 5 6 7 8 9 10

ON

0=OFF

1=

11 12

4~6

 to set the intensity of

3.Program Mode

In this mode, dip switches 10 & 12 are flipped to 

ON

 and dip 11 to 

OFF

.  With the dips number 1, 2 and 3, we can select one of three built-in programs. With dips 4, 5 & 6

it is possible to control the general dim level, and using dips 7, 8 & 9, it is possible to control the speed of these programs. See closed tables:

1 2 3 4 5 6 7 8 9 10

11 12

1 2

Num. 1            1   0    0

Num. 3            1   1    0

Num. 2            0   1    0

Program 

1 2 3

ON

0= OFF

1=

1 2

   0                  0   0    0

Intensity

5 6

4

   14%             1   0    0

   28%             0   1    0

   43%             1   1    0

ON

0= OFF

1=

Intensity

   57%             0   0    1

   71%             1   0    1

   86%             0   1    1

   100%           1   1    1

8 9

7

   0                  0   0    0

Speed

   14%             1   0    0

   28%             0   1    0

   43%             1   1    0

ON

0= OFF

1=

Speed

   57%             0   0    1

   71%             1   0    1

   86%             0   1    1

   100%           1   1    1

Program 1

: 7 colors changing without fade: Red, Green, Blue, Red/Green, Red/Blue, Blue/Green, White.

Program 2

: Red to Green, Green to Blue, Blue to Red, short transition. With Fade.

Program 3

: Red to Green, Green to Blue, Blue to Red, long transition , independent middle colors. With Fade.

Red

(SW1~3)

Green

(SW4~6)

Blue

(SW7~9)

Intensity

000

0

100

14%

010

28%

110

43%

000

100

010

110

000

100

010

110

2.Manual Control Mode

CONNECTING DIAGRAM (EXAMPLES)

A

. Installation with DMX control. Setup to 

DMX 2 MODE

 ( on Outputs 1, 2, 3 & 4 one channel controls the same color in alll of theses outputs). 

     In the same way, other 3 independent channels manage the whole color on outputs 5, 6, 7 & 8. Another channel is assigned as General Dimmer.
     Each output allows to connect up to 3 A load max.
    

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

CH 1: Red Outputs 1,2,3,4
CH 2: Green Outputs 1,2,3,4
CH 3: Blue Outputs 1,2,3,4
CH 4: Red Outputs 5,6,7,8
CH 5: Green Outputs 5,6,7,8
CH 6: Blue Outputs 5,6,7,8
CH 7: General Dimmer

1 2 3 4 5 6 7 8 9 10

ON

0=OFF

1=

11 12

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

Up to 3 A max. load (50 x LED LINE 10 max.)

CH 1: Red Outputs 1,2,3,4,5,6,7,8
CH 2: Green Outputs 1,2,3,4,5,6,7,8
CH 3: Blue Outputs 1,2,3,4,5,6,7,8
CH 4: General Dimmer

1 2 3 4 5 6 7 8 9 10

ON

0=OFF

1=

11 12

B.

 Installation with DMX control. Setup on DMX 1 MODE ( On all outputs one channel manage the common colors of these outputs), also,another channel is assigned 

    as General Dimmer.  Each output allows to connect up to 3 A load max.

To next DMX control device

From a DMX console

To next DMX control device

From a DMX console

ON

0=OFF

1=

EN

User Manual

MINIDIM 8

MINIDIM 8                                                  User Manual/Manual de uso                                               Pag 2

Summary of Contents for MINIDIM 8

Page 1: ...ON 0 OFF 1 ON 0 OFF 1 Qty of DMX Channels Mode Dip Switches Function DMX 8 000 25 Each color on each output can be controlled independently 24 channels General Dimmer DMX 4 001 13 Outputs are grouped in blocks of 2 OUTPUT 1 2 The colors of each groups are common 12 channels General dimmer DMX 1 011 4 All Outputs obbey the same color control it is common in the whole outputs 3 channels General Dimm...

Page 2: ...n with DMX control Setup to DMX 2 MODE on Outputs 1 2 3 4 one channel controls the same color in alll of theses outputs In the same way other 3 independent channels manage the whole color on outputs 5 6 7 8 Another channel is assigned as General Dimmer Each output allows to connect up to 3 A load max Up to 3 A max load 50 x LED LINE 10 max Up to 3 A max load 50 x LED LINE 10 max Up to 3 A max load...

Page 3: ...FF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 ON 0 OFF 1 Nº de canales DMX Modo Dip Switches Función DMX 8 000 25 Cada color en cada una de las 8 salidas puede ser controlado independientemente 24 canales Intensidad general DMX 4 001 13 Las salidas se agrupan en bloques de 2 OUTPUT 1 2 Los colores en ese grupo son comunes 12 canales Intensidad general DMX 2 010 7 Las salidas se agrupan en bloques de 4 OUT...

Page 4: ...ste modo los dip 10 y 12 se configuran en ON y el dip 11 a OFF on los dip 1 3 se selecciona uno de los 5 programas incorporados Con los dip 4 6 es posible controlar el nivel de dimmerización general y usando los dip 7 9 es posible controlar la velocidad de los programas Ver tabla adjunta Hasta 3 A de carga max 50 x LED LINE 10 max Hasta 3 A de carga max 50 x LED LINE 10 max Hasta 3 A de carga max ...

Reviews: