![Work Microwave VHCU User Manual Download Page 38](http://html1.mh-extra.com/html/work-microwave/vhcu/vhcu_user-manual_996765038.webp)
Satellite Upconverter Manual
WORK Microwave
38 / 49
V151207
4.4 Web Browser Interface
A web server is included within the firmware of the unit. It can be accessed with any web browser, preferable
with Mozilla Firefox. A SSL based secure connection is also supported.
http://[IP-address]
(example: http://192.168.10.20)
https://[IP-address]
(example: https://192.168.7.120)
[IP-address] is the IP-
address of the unit’s M&C Ethernet interface, which can be configured e.g. by the front
panel menu, and which has to match the address scheme of the IP-network, to which the unit is connected. If
an IP connection through a router is required also check for proper configuration of the network mask and the
gateway address.
The web browser needs to be set to “Cookies enabled”.
After getting access to the web-server, a login is required.
Figure 17: Login page
Possible user names are: ‘root’, ‘user’ or ‘monitor’. The entry is case sensitive. The passwords are as default
identical to the user names, but can be changed through the browser interface. User names cannot be
changed.
The different user names correspond to different authorization levels, the following rules apply:
‘root’: all interactions supported by the web
-browser interface can be executed.
‘user’: all interactions except reconfiguration of M&C interfaces or change of passwords can be ex
ecuted.
‘monitor’: only reading out of parameters can be executed.
After login the first configuration page is shown. The web interface is segmented in three main areas.