6
General notes
6 720 610 577 GB (03.02)
done. Repeated venting will reduce the quantity of water in the
system and this must be replenished for safe and satisfactory
operation of the appliance.
Should water leaks be found in the system or excessive venting is
required then a service engineer must be contacted to inspect the
installation and rectify any fault.
Only additives that are compatible with aluminium may be used in
the system. Any incompatible additive used will invalidate the
guarantee.
Condensate drain
This is a condensing appliance and the terminal will, at times, give
out a plume of water vapour. This is quite normal.
The appliance produces quantities of condense which is dis-
charged regularly through the siphon.
Clearances
Your installer will have provided adequate space around the appli-
ance for safety and servicing access. Do not restrict this space
with the addition of cupboards, shelves etc. next to the appliance.
Room thermostat
A room thermostat with volt free contacts (i.e. battery operated)
may be fitted to control the central heating. Refer to the instruc-
tions supplied with the thermostat for information on siting and
setting. A programmable thermostat may also be used with this
appliance to provide additional timed control of the central heat-
ing.
Left-hand side
5 mm
Right-hand side
5 mm
In Front
600 mm
Above Casing (Vertical Flue)
75 mm
Above Flue Turret
30 mm
Below
200 mm
Table 1