6 720 612 220 GB (05.09)

 

Operating elements

 

a

 

Turn selection knob 

 in the 

 

+

 

 

direction: Select upper Menu/Info 
texts or set value higher
Turn selection knob 

 in the 

 

-

 

 

direction: Select bottom Menu/Info 
texts or set value lower
Press selection knob 

Open or save Menu/value

 

b

 

Operating mode switch:

 

Heating

Hot water

 

Automatic mode Automatic mode
Continuous 

 

High

 

 or 

 

On

 

Continuous 

 

On

 

Continuous 

 

Low

 

 or 

 

Off

 

Automatic mode

Continuous 

 

Frost

 

Continuous 

 

Off

c

 

Button 

To advance the next switching time 
and the associated operating mode 

 = 

 

High

 

 or 

 

On

 

 = 

 

Low

 

 or 

 

Off

 

 = 

 

Frost

 

 

for the heating to the current time.

 

d

 

Button

To advance the next switching time 
and the associated operating mode 

 

On

 

 or 

 

Off

 

 for hot water heating to the 

current time

 

e

 

Button

: Display values

 

f

 

Button

: Open Menu

 

g

 

Button

Show previous menu level

 

h

 

Button

:

Delete/Reset value

i

 

In order to simplify this document, 
the operating elements and oper-
ating modes will sometimes only 
be identified by symbols, e.g. 

 or 

.

advance

advance

info

menu

 

Symbols

 

Current room temperature 
(only with 

 

RT 10

 

 )

Flashing segment:
current time from 

 

09:30 

 

 until 

 

09:45 

 

Full segments: 
Heating program current day for 

 = 

 

High

 

 or 

 

On

 

 

(1 Segment = 15 min)
Empty segments: 
Heating program current day for 

 = 

 

Low

 

 or 

 

Off

 

 

(1 Segment = 15 min)
No segments: 
Heating program current day for 

 = 

 

Frost

 

 (no segments)

Operating mode 

 

High

 

 or 

 

On

 

 for 

heating
Operating mode 

 

Low

 

 or 

 

Off

 

 for 

heating
Operating mode 

 

Frost

 

 or 

 

Off

 

 for 

heating
Automatic mode for heating
Holiday program
Burner on

 

+

 

Upper Menu/Info texts or value 
higher

 

-

 

Bottom Menu/Info texts or value 
lower

 

ok

 

Open or save Menu/value
Call up parent menu level
Delete/Reset value
Advance next switching time and 
the associated operating mode 

 = 

 

High

 

 or 

 

On

 

 = 

 

Low

 

 or 

 

Off

 

 = 

 

Frost

 

 

for the heating to the current time.
Advance next switching time and 
the associated operating mode 

 

On

 

 

or 

 

Off

 

 for hot water heating to the 

current time.

9

21

15

3

advance

advance

Summary of Contents for TD 200

Page 1: ...ances with bus enabled Heatronic 3 and RT 10 TD 200 6 720 612 220 00 1R Order no 7 719 002 506 6 720 612 220 GB 05 09 OSW INSTALLATION USER INSTRUCTIONS CUSTOMER CARE GUIDE 6 720 612 220 00 1R TD 200...

Page 2: ...our company The TD 200 offers everything you can expect from a modern heating control It is both reliable and energy saving Like all Bosch Group products the TD 200 has been produced and tested accor...

Page 3: ...et factory settings 17 5 MAIN MENU 18 5 1 MAIN MENU Overview 18 5 2 Operating instructions in brief 19 5 3 Holiday 19 5 4 Heating 20 5 4 1 Program 20 5 4 2 Heating levels 21 5 4 3 Optimum Start 21 5 5...

Page 4: ...es sories in wet rooms Symbols Signal words indicate the seriousness of the haz ard in terms of the consequences of not following the safety instructions Caution indicates that minor damage to propert...

Page 5: ...oom temperature The TD 200 has a battery power reserve of approx 20 months If the TD 200 has not received any power for longer than 20 months the time and date are deleted All other settings are maint...

Page 6: ...EN60730 2 7 1992 Electro Magnetic Compatibility and Radio Spectrum Matters ERM Short Range Devices SRD ETSI EN300 220 1 EC Directives European Union Law Directive 2000 R4 EC Low Voltage Directive 73...

Page 7: ...ce parts see installation instructions of the heating device Fig 2 Remove the outer casing Fig 3 Remove cover and blanking plate Fig 4 Insert TD 200 in the guides Danger risk of electric shock B Befor...

Page 8: ...8 Installation 6 720 612 220 GB 05 09 Fig 5 Lock TD 200 into place and replace cover 6 720 612 220 04 1R 2 1 3 4...

Page 9: ...nting Fig 6 Select mounting location Fig 7 Wall mounting socket accessory B Make electrical connections see Figure 10 Fig 8 Locate TD 200 upper part and slide into frame i The mounting surface on the...

Page 10: ...he cables in the case of external inductive influences This ensures that the cables are shielded against external influences e g heavy current cables overhead contact wires transformer stations radio...

Page 11: ...elements and symbols Fig 12 Standard display when connected RT 10 9 12h 15 18 21 24h 3 6 6 720 612 220 01 1O menu info a b c d e f h g advance advance i If no RT 10 is connected this standard display...

Page 12: ...simplify this document the operating elements and oper ating modes will sometimes only be identified by symbols e g or advance advance info menu Symbols Current room temperature only with RT 10 Flash...

Page 13: ...sociated operating mode High or On Low or Off Frost for the heating to the current time The display shows Heating Advance on and the altered data If the next switching time of the heating pro gram is...

Page 14: ...ntrolled to the hot water temperature set on the heating appli ance The hot water program is ignored Continuous low mode Heating with RT 10 The TD 200 continuously controls to the room temperature set...

Page 15: ...quired menu item is highlighted In the example Select Mo Fr B Press selection knob to confirm the selection The next submenu with the pre programmed switching times and operating modes P1 to P6 is dis...

Page 16: ...B Turn selection knob to set the operating mode In the example Set Low B Press selection knob to save the operat ing mode The operating mode saved is also accepted for the individual days Monday to Fr...

Page 17: ...le Heating Program appears when resetting this help text Fig 21 Help text Reset to factory B Press the selection knob to return to the Menu Reset all settings If the standard display is set B Keep and...

Page 18: ...6 Monday Tuesday Sunday back P1 P2 P6 Reset to factory Heating levels1 back 21 High Low Frost Optimum Start1 21 Domestic Hot Water back Program back 22 Mo Fr back P1 P2 P6 Sa Su back P1 P2 P6 All days...

Page 19: ...Holiday program starts immediately If the date for Start is from tomorrow or later the Holiday program starts at 00 00 12 00 am on the day set Holiday End The Holiday program ends at 23 59 11 59 pm on...

Page 20: ...imes per day with three different operating modes High Low Frost Heating without RT 10 Maximum six switching times per day with two different operating modes On Off optionally the same times for each...

Page 21: ...e To enable the required room temperature to be attained approx 1 hour after the programmed switching time High the TD 200 calculates the optimum time point for the heating start Example required room...

Page 22: ...e heat exchanger inside the heating appliance does not remain heated as a result hot water is not available until after a longer period of drawing off the hot water For a heating system with hot water...

Page 23: ...rmat Time The format for the time display can be selected between 12h am pm or 24h here Date The format for the date display can be selected between MM DD YYYY or DD MM YYYY here D Day M Month Y Year...

Page 24: ...mode or special mode for the heating Requested room temperature 25 0 C Room temperature requested by the RT 10 only with RT 10 Actual room temperature 22 0 C Room temperature measured at the RT 10 onl...

Page 25: ...ther faults are no longer active 7 4 Maintenance The expert can set and activate the interval for the requisite maintenance here 0 months means that the function is not availa ble 7 5 Service address...

Page 26: ...quipped Yes No is automatically set on commissioning with RT 10 to Yes 8 Service display If the Service button is pressed on the heating appliance and the Service mode is active the fol lowing display...

Page 27: ...tc can lead to the heating in the adjoining rooms remaining too low A significant amount of energy can be saved by lowering the room temperature A reduc tion in temperature by 1 K C can result in up t...

Page 28: ...l No Bus communica tion The RT 10 using the bus no longer responds Have the bus connection checked and if necessary the interruption rectified by a professional Heating appliance using the bus no long...

Page 29: ...oved by an expert see Installation Instructions of the RT 10 Excessive room tempera ture fluctuations Temporary effect of heat from other sources on the room e g from sun shine room lighting TV firepl...

Page 30: ...30 C not higher than Low in 0 5 K increments C Heating Optimum Start1 Off Off On Domestic Hot Water Program see table on page 33 Domestic Hot Water Circ pump runs 4 h 0 h 7 h in 1 h increments Genera...

Page 31: ...ion off 0 120 months months Maintenance Confirmation maintenance Yes No Yes No Service address Telephone number 012345 6789 max 20 characters Service address Name ABCD max 20 characters System info In...

Page 32: ...ing with RT 10 Mo Fr 20 06 30 16 08 30 20 16 30 7 22 30 Sa Su 20 07 00 16 09 00 20 16 00 7 23 00 All days without RT 10 Mo Fr On 06 30 Off 08 30 On 16 30 Off 22 30 Sa Su On 07 00 Off 09 00 On 16 00 Of...

Page 33: ...Factory setting Mo Fr On 06 30 Off 08 30 On 16 30 Off 22 30 Sa Su On 07 00 Off 09 00 On 16 00 Off 23 00 All days Personal settings Mo Fr Sa Su All days Monday Tuesday Wednes day Thursday Friday Saturd...

Page 34: ...pert settings 25 Maintenance 25 Operating instrcutions in brief 25 Overview 25 Service address 25 System errors 25 System info 26 G Greenwich time format 23 H Heating appliance settings 20 I Installat...

Page 35: ...t settings 31 Main Menu 30 Time programs tables 32 Domestic hot water program 33 Heating program 32 Specifications for room temperature controller Accessories 5 Standard package 5 Technical data 5 Sta...

Page 36: ...R INSTRUCTIONS CUSTOMER CARE GUIDE Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 01905 754624 Fax 01905 754619 www worcester bosch co uk Worcester Bosch Group is a trading name of B...

Reviews: