USER INSTRUCTIONS & CUSTOMER CARE GUIDE

INTR

ODUCTION

8 716 115 385a (07.200)

GENERAL NOTES

4

To get the best from your boiler please read
these instructions carefully.

SEALED HEATING SYSTEMS

This boiler is fitted to a sealed heating system
which is pre-pressurised. Your installer will
advise you of the minimum and maximum
pressure which should be indicated on the
pressure gauge.

Check regularly that the pressure is maintained
and contact your installer or maintenance
engineer if a permanent significant drop in
pressure is indicated on the pressure gauge.
If the system loses pressure it should be re-
pressurised and the cause of the fall
investigated.

CENTRAL HEATING SYSTEMS

During the first few hours of operation of the
central heating system, check that all radiators
are being heated evenly. If the top of a radiator
is at a lower temperature than the bottom
then it should be vented by releasing air
through the venting screw at the top of the
radiator. Ask your installer to show you how
this is done.

This boiler is fitted to a sealed system;
repeated venting will reduce the quantity of
water in the system and this must be
replenished for safe and satisfactory operation
of the boiler.

Should water leaks be found in the system or
if excessive venting is required, then a service
engineer must be contacted to inspect the
installation and rectify any fault.

Only additives that are compatible with
aluminium may be used in the system. Any
incompatible additive used will invalidate the
guarantee.

CONDENSATE DRAIN

This is a condensing boiler and the terminal
will, at times give out a plume of water vapour.
This is quite normal.

The boiler also produces quantities of
condensate which is discharged regularly by
a trap within the boiler via a pump and pipe
to drain. This pipe must not be blocked or
altered in any way.

CLEARANCES - SERVICE

Your installer will have provided adequate
space around the boiler for safety and servicing
access. Do not restrict this space with the
addition of cupboards, shelves etc. next to
the boiler.

ROOM THERMOSTAT

A room temperature controller and
programmer should be fitted to control the
central heating. Refer to the instructions
supplied with the thermostat for information
on siting and setting.

THERMOSTATIC RADIATOR VALVES

RVs should fitted to all but one of the radiators
(or at least those in the sleeping
accommodation). The radiator without the
TRV must be in the same room as the room
thermostat, and must be uncontrolled and
unrestricted. The thermostatic radiator valves
should conform to the requirements of
BS2767:10.

GENERAL NOTES

600mm

15mm

5mm

5mm

610mm

1200mm

865mm

Summary of Contents for GREENSTAR HIGHFLOW 440CDi

Page 1: ...C13 C33 C53 NATURAL GAS GREENSTAR HIGHFLOW 440CDi GC NUMBER 47 406 24 GREENSTAR HIGHFLOW 550CDi GC NUMBER 47 406 25 LIQUID PETROLEUM GAS GREENSTAR HIGHFLOW 440CDi GC NUMBER 47 406 26 GREENSTAR HIGHFL...

Page 2: ...GROUP TECHNICAL SUPPORT DISTANCE LEARNING AND TRAINING COURSES ARE AVAILABLE FROM WORCESTER BOSCH GROUP THIS BOILER MUST BE INSTALLED BY A CORGI REGISTERED COMPETENT PERSON FAILURE TO INSTALL CORRECT...

Page 3: ...you for purchasing a Greenstar gas fired condensing combination boiler manufactured by Worcester Bosch Group The company prides itself on manufacturing boilers to the strictest quality control standar...

Page 4: ...nside or within the vicinity of the boiler Chemically aggressive substances can corrode the boiler and invalidate any warranty FITTING MODIFICATIONS Fitting the boiler any controls to the boiler and r...

Page 5: ...event of any warranty work and may be required by the local Building Control Inspector NOTE BENCHMARK STANDARD Benchmark is a code of practice for correctly installing commissioning and servicing of...

Page 6: ...f the boiler Should water leaks be found in the system or if excessive venting is required then a service engineer must be contacted to inspect the installation and rectify any fault Only additives th...

Page 7: ...spite of the requirements of BS 6798 and BS 5440 there is no need for ventilation openings to be provided in the compartment because of the low heat loss from the boiler casing if the clearances shown...

Page 8: ...B I E H M G K A MASTER SWITCH FOR ON OFF B MAINS ON OFF INDICATOR FAULT DIAGNOSTIC LIGHT C CENTRAL HEATING TEMPERATURE CONTROL D BURNER ON INDICATOR LIGHT GREEN E FAULT RESET BUTTON F SERVICE BUTTON...

Page 9: ...G YOUR APPLIANCE 8 716 115 220a 07 2008 CONTROLS 7 CONTROLS TO ACCESS THE CONTROLS Pull the centre top of the cover panel to allow the cover to open TO ACCESS THE FILLING LOOP CONNECTION Pull the fron...

Page 10: ...flow temperature This occurs every time the mains supply has been interrupted Switching off Switch off the appliance by pressing the master switch The blue indicator light goes out SETTING THE CENTRA...

Page 11: ...TEMPERATURE The hot water temperature can be set to between approx 45 C and 65 C using the temperature control ECO INDICATOR NOTE If your boiler has an in built fascia mounted programmer and the main...

Page 12: ...second and the mains indicator blue light will flash also The display shows a fault code To reset boiler press the reset button The reset button will no longer be illuminated and the mains indicator...

Page 13: ...your boiler receives regular servicing and maintenance checks from a competent person beyond the initial 2 year guarantee period If you would like to know more about a Worcester Bosch Group service c...

Page 14: ...on boiler set too low Increase CH flow temperature control setting Air trapped in heating system Bleed radiators and recharge heating system Desired room temperature exceeded by large amount Radiator...

Page 15: ...Benchmark Checklist OR Our Field Service Engineer finds no fault with the boiler see Note OR The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipment not...

Page 16: ...ay on for relatively long periods but will use less gas than a boiler that continually switches on and off CENTRAL HEATING SYSTEMS WITH ROOM THERMOSTATS THERMOSTATIC RADIATOR VALVES The temperature co...

Page 17: ...th a window so the warm air from the radiator heats the colder incoming air from the window The performance of the radiator will be affected if the curtains are allowed to drape over the radiator or s...

Page 18: ...inspection has been carried out to the satisfaction of Bosch Thermotechnology Ltd when requested These should be part of the Benchmark Checklist Any product or part returned for servicing under the g...

Page 19: ...f your new Greenstar boiler and will assist us in maintaining an effective and efficient customer service by establishing a reference and permanent record for your boiler This does not affect your sta...

Page 20: ...20 6677 Dedicated to heating comfort Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 01905 754624 Fax 01905 754619 Worcester Bosch Group is a brand name of Bosch Thermotechnology Ltd...

Reviews: