INSTALLATION & SERVICING INSTRUCTIONS
16
ROOM SEALED FLUE OPTIONS
6-720-611-730b (12.05)
The diagrams (opposite) show the components
used and the maximum flue length for each
configuration of 100mm and 125mm flues.
Only straight flue sections can be reduced in
length by cutting.
The flue terminal end can be fitted from the
inside or outside of the building.
Horizontal 125mm and Vertical 100mm and
125mm flue kits are available with separate
instructions. Contact your supplier or Worcester
Bosch.
IMPORTANT:
All horizontal sections must rise away from
the boiler by 52mm per metre (3°) to allow
the condensate to drain back to the boiler.
A - Horizontal terminal
B - Straight flue extension
C - Flue bend 90° & 45°
D - Flue bend 45°
E - Vertical Terminal
Calculating the flue length:
Measure the total flue length required, noting that
the maximum straight flue length including the
terminal is:
Horizontal 60/100mm : 4000mm
Horizontal 80/125mm : 13000mm
Vertical 60/100mm : 6400mm
Vertical 80/125mm : 15000mm
Then reduce the total straight flue length for each
extra flue bend (excluding the flue elbow) by:
2000mm for 90°
1000mm for 45°
Flue Extension lengths:
Horizontal & Vertical 60/100mm : 1000mm
Horizontal & Vertical 80/125mm : 1030mm
Flue Terminal lengths:
Horizontal 60/100mm : 800mm
Horizontal 80/125mm : 1200mm
Vertical 60/100mm : 1140mm
Vertical 80/125mm : 1365mm
ROOM SEALED FLUE OPTIONS
E
D
C
A
B
A
B
A
B
A
C
B
A
D
D
B
A
C
C
B
A
C
C
B
A
C
C
C
E
B
D
D
C
E
B
C
L=100mmØ 250 - 600mm
L=125mmØ 350 - 1200mm
L
100mmØ x4
125mmØ x12
L
L=100mmØ 400 - 4000mm
L=125mmØ 350 - 13000mm
L=100mmØ 2000mm
L=125mmØ 11000mm
100mmØ x2
125mmØ x10
L
100mmØ x2
125mmØ x10
L=100mmØ 2000mm
L=125mmØ 11000mm
L=125mmØ 9000mm
125mmØ x8
L
L=125mmØ 9000mm
125mmØ x8
Min.
120mm
L
L=125mm 7000mm
125mmØ x6
Min.
120mm
L
L=100mmØ 4400mm
L=125mmØ 13000mm
100mmØ x4
125mmØ x12
Min.
120mm
L
L=100mmØ 2400mm
L=125mmØ 11000mm
100mmØ x2
125mmØ x10
Min.
120mm
L
L