Central heating systems

All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be bled 
by releasing air through the bleed screw at the top of the radiator. 
Ask your installer to show you how this is done.

This boiler is fitted to a sealed system. Should water leaks be found or if excessive bleeding is required, then a service engineer must 
be contacted to inspect the installation and rectify any fault.

Only additives that are compatible with aluminium may be used in the system. Any incompatible additive used will invalidate the 
guarantee.

Pluming and condensate drain

This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour. This is quite normal.

The boiler produces condensate which is discharged regularly by a syphon within the boiler via a plastic pipe to a drain. This pipe 
must not be blocked or altered in any way.

Room thermostat / programmer

A room thermostat / programmer must be fitted to control the central heating. This controls the times and temperatures of the 
central heating, preventing the boiler from firing unnecessarily. Refer to the instructions supplied with the thermostat and 
programmer for further information.

Thermostatic radiator valves

Thermostatic radiator valves must be fitted in sleeping accommodation. It is recommended that this type of valve is fitted to all but 
one of the radiators. The remaining radiator, where the room thermostat is located, must be uncontrolled and left open.

Pump over run function

After the boiler has finished a demand for central heating or hot water, the pump may continue to run for a short while to dissipate 
the heat from within the boiler.

Pump anti-seizure

If there has been no heating demand for 24 hours, the boiler will run the system pump for a few seconds to reduce the possibility of 
pump seizure during long periods of inactivity.

Summary of Contents for Greenstar CDi Compact ErP

Page 1: ...away from the building call the National Gas Emergency Service on 0800 111 999 L P G boilers Call the supplier s number on the side of the gas tank These appliances are for use with Natural Gas or L P...

Page 2: ...nsing combination appliance manufactured by Worcester Bosch Group Thecompanypridesitselfonmanufacturingappliances to the strictest quality control standards throughout every stage of production Worces...

Page 3: ...em 9 3 1 6 Domestic hot water eco and preheat modes 9 3 1 7 Domestic hot water preheat mode manual activation Eco mode off 10 3 1 8 Domestic hot water preheat mode timed activation with facia timer or...

Page 4: ...n component list etc 1 2 Safety precautions If you smell gas Agasleakcouldpotentiallycauseanexplosion Ifyousmellgas observe the following rules Prevent flames or sparks Do not smoke use a lighter or s...

Page 5: ...enchmark Checklist The completed Benchmark Checklist will be required in the event of any guarantee work and may be required by the local Building Control Inspector 2 3 Benchmark standard The Benchmar...

Page 6: ...ce engineer symbol boiler is set to maximum or minimum output for service 10 The blue light is ON when the boiler is in an operational mode It will also flash to indicate a fault 3 Eco button 4 Reset...

Page 7: ...en the boiler is set to maximum or minimum output Alert Displays along with the boiler status code and diagnostic code during a fault condition Service mode Displays when a qualified service engineer...

Page 8: ...this will be indicated on the digital display This is not the room temperature but the flow temperature through the radiators The e point provides guidance for the maximum temperature setting for opti...

Page 9: ...facturer s instructions 3 1 5 Setting the flow temperature for domestic hot water system 1 Turnthe hotwater temperaturecontrolknob tothedesiredlevelbetween40and60 C this will beshownonthedigitaldispla...

Page 10: ...n can be selected via the programmer Programmer hot water channel ON periods PreHeat mode is active and indicated on the appliance display Programmer hot water channel OFF periods Eco mode active and...

Page 11: ...then the system requires re charging Contact your installer or maintenance engineer if a permanent significant decrease or increase in pressure is indicated on the pressure gauge Fig 2 Optimum system...

Page 12: ...ap between the two sections of the filling loop 3 Turn the white knob to the left this will allow water to fill the system 4 When the pressure shown on the appliance facia pressure gauge reaches betwe...

Page 13: ...CAUTION Restricted space The boiler may overheat Do not restrict this space with the addition of cupboards shelves etc next to the boiler NOTICE Combustible and corrosive materials Chemically aggressi...

Page 14: ...performance it is essential that your appliance receives regular servicing and maintenance checks from a competent person beyond the initial guarantee period If your Greenstar gas fired appliance shou...

Page 15: ...d re pressurise the heating system Low system water pressure Re pressurise the system refer to page 12 Desired room temperature too high Thermostatic radiator valves are set to high Turn down thermost...

Page 16: ...in andtheblueoperation faultlightwillcontinuetoflash Due to the internal safety systems of your Greenstar CDi CompactErP boiler some codes cannot be cleared by a simple reset Please contact Worcester...

Page 17: ...crowaveable heating pack the sort used for muscular aches and pains or a cloth soaked in hot water to the exterior of the pipe close to the point of blockage Hot water but not boiling can also be pour...

Page 18: ...n the Benchmark Checklist Our Field Service Engineer finds no fault with the boiler The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipment not supplied...

Page 19: ...ng the thermostatic radiator valves Room thermostats Reducing the setting of the room thermostat by 1 C can reduce fuel consumption by up to 10 New control systems Upgrade your heating control system...

Page 20: ...service has been carried out to the satisfaction of Bosch Thermotechnology Ltd when requested These should be documented as a part of the Benchmark Checklist The boiler has been used only for the nor...

Page 21: ...phon within the boiler via a plastic pipe to a drain This pipe must not be blocked or altered in any way Room thermostat programmer A room thermostat programmer must be fitted to control the central h...

Page 22: ...22 Greenstar CDi CompactErP 6 720 813 277 2014 09 Notes...

Page 23: ...23 Greenstar CDi CompactErP 6 720 813 277 2014 09 Notes...

Page 24: ...SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a bran...

Reviews: