6 720 611 137 GB (03.02)
Maintenance
39
Fig. 61
8.3.5
Electrode assembly
B
B
Use a new seal if the existing seal is damaged.
8.3.6
Pressure Relief Valve
B
Drain the appliance.
B
Disconnect the drain pipe from the valve. Refer to
fig. 32.
B
Pull-out the clip securing the valve.
B
Pull-out the valve.
B
Ensure that the replacement valve is fully entered
before fitting the clip.
8.3.7
Burner
B
8.3.8
Primary Heat Exchanger
B
Drain the appliance.
B
Check that the gas supply is turned off.
B
Check that the appliance is electrically isolated.
B
Remove the fan assembly complete with the gas/air
tube and mixer assembly. Refer to section 8.3.2.
B
Remove the burner. Refer to section 8.2.
B
Disconnect the sensors. Refer to section 8.3.3.
B
Undo the central heating flow union.
B
Undo the grey plastic cap at the base of the heat
exchanger.
B
Unscrew and remove the condensate trap. Refer to
section 8.2.
B
Unscrew and remove the two screws securing the
heat exchanger top bracket to the rear panel.
B
Lift up the flue duct, item 271, refer to fig. 2.
B
Pull forward from the top and lift the heat exchanger
from the casing.
B
Transfer components, as necessary, to the new heat
exchanger.
B
Ensure that all the seals are in place and all of the
connections are tight before re-commissioning the
appliance.
Fig. 62
6 720 610 602 - 04.1O