6 720 611 137 GB (03.02)
36
Maintenance
Diaphragm in mixer unit
B
Open mixer unit (29).
B
Carefully withdraw diaphragm (443) from fan intake
tube and check for soiling and splits.
Fig. 55
B
Carefully refit diaphragm (443) the correct way
round into the fan intake tube.
B
Seal the mixer unit (29).
Siphon
B
Unscrew the clip and disconnect the pipe to the
siphon.
B
Remove the yellow plug to drain the siphon.
B
Unscrew the securing nut from beneath the side
facia and remove the siphon. Refer to figure below.
B
Refit and prime the siphon.
Fig. 56
Electrical wiring
B
Check the electrical wiring for physical damage and
replace any damaged wires.
B
Take care not to damage diaphragm
(443) when removing and refitting it.
i
The flaps of the diaphragm (443) must
open upwards.
1.
2.
3.
443
29
6 720 610 790-07.2R
6 720 611 137 - 22. 1O
Siphon
Condensate
Drain