Control panel overview
Fig. 4
Control panel
[1]
Display
[2]
and
keys: To navigate through menus and increase/decrease
settings
[3]
d
key: Return/back
[4]
OK key: Save settings
[5]
Menu key
[6]
Hot water key: Hot water mode on/off, adjusting the hot water
temperature (only available if optional integral diverter valve
kitfitted)
[7]
Heating key: Heating mode on/off, set the maximum flow
temperature
[8]
Burner display: Illuminates when the burner is alight.
4.2
Symbols in the display
Table 3 Symbols in the display
The heating and hot water system has been set up by the installer to the
appliance’s and controls optimum settings.
▶ It is advised to make a note of these settings before adjusting so that
you can return to these optimum settings in the future.
4.3
Adjusting the appliance flow temperature
4.3.1
Heating key
The key is used to set the max. flow temperature. The maximum flow
temperature can be set between 30 °C and 88 °C
1)
. The current flow
temperature is shown on the display.
With underfloor heating systems observe the maximum permissible flow
temperature.
▶ Press the
(
key.
The set maximum flow temperature appears.
▶ Press the
or
keys to set the desired maximum flow temperature.
Table 4 Maximum flow temperature
▶ To save the setting, press the
key or wait for 2 seconds.
The symbol
appears for a short time.
If a time program is activated and set on
auto
press the
key to switch
to
Advance
. Time programs are available with Key (accessories).
auto
: Heating is switched on and off according to programmed times for
heating.
Advance
: Switch to
Advance
to move to the next on or off time and
directly switch on or off heating.
Symbol
Explanation
Connection with the Wi-Fi network (only available with
accessories)
Connection with RF transmitter, e.g. II RF room
thermostat (only available with Key accessories)
Central heating adjustment
auto
: Heating is switched on and off according to
programmed times for heating
.
Advance
: Move to the next on or off time and directly
switch on or off heating.
Central heating off
Hot water adjustment (only available with optional integral
diverter valve kit)
Hot water off
Displays with the appliance status code and diagnostic
code during a fault condition.
Holiday symbol
Cleaning mode to enables the boiler to be cleaned without
making changes to the touch panel.
0010018565-001
1
2
3
5
6
7
8
4
Central heating or hot water can be switched either
permanently on or off.
Energy consumption
1)
Gas consumption
Electricity consumption
1) The energy values shown are an estimation based on internal data of the
appliance. Under real world conditions, many factors influence the energy
consumption and the shown values will deviate from the values of an energy
meter. The information is for indication only and should not be used for billing
purposes. The values can be used for relative comparison of energy consumption
between different days/weeks/month.
1) The maximum value can be reduced by the service technician.
Supply temperature
Sample application
Approx. 50 °C
Underfloor heating system
Approx. 75 °C
Radiator heating system
Approx. 82 °C
Convector heating system
Symbol
Explanation
kWh