Reference: WX-B-009-01
Title: Product Performance
Specification
Rev./Status: 0.1 / Draft
Model : FX15 FX25 FX55
Page
10
of
16
•
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Common mode:
•
6kV/2 ohm criteria C for Europe.
•
6kV/12 ohm criteria C for Nafta.
Parameters:
•
Ring-wave
(100kHz)
•
From +/3kV to +/-6kV in steps of 1 kV.
•
10 shots per combination.
•
One shot per minute.
•
Serial impedance: 2 Ohm for Europe, 12Ohm for Nafta
•
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Reference: IEC61000-4-5 and for USA: 3135 019 8029 Reliability evaluation.
Requirements:
•
Apparatus should fulfil the leakage current requirements of IEC60065 point 9.1.1 (UAN-D1631)
•
Defects or permanent deviations are not allowed.
3.1.3
Mains Drop-out Immunity
The product shall withstand mains failures of:
•
Variation 0%(=100% dip) at T-event = 50 mSec. Performance criterion B
•
Variation 40%(=60% dip) at T-event = 100 mSec. Performance criterion B
•
Variation 0%(=100% dip) at T-event = 5 Sec. Performance criterion C
Additional for USA apparatus: See 3135 019 8029 Reliability evaluation.
•
Variation 0%(=100% dip) at T-event = 100 mSec in standby mode. Performancecriterion B
Requirement:
No misoperation and no interference of user in order to guarantee continuation of performed function.
Reference: IEC61000-4-11 For measuring method refer to UAN-D1724, as far as applicable.
Performance criterions according to IEC61000-4-4 Amendment 1
Performance Requirement
Criterion A - No any degradation of specification.
Criterion B - Temporary degradation / self recoverable.
Criterion C - No damage, resolvable hang-up.
Criterion D - Not recoverable loss of function.
3.1.4 Power
Consumption
Power consumption at nominal AC input:
1. Docking mode at 1/8 P-rated output power
:
≤
W
2. Low Power Standby Mode
:
≤
0.5 W