http://www.woosim.com
2007-10-26
12
2.5. Set operation mode
1.
Press the
Mode Button
until the
Error Lamp
twinkles 5 times
2.
Change the mode and option using the
Mode Button
and
the
Feed Button
according to the
MODE code(Table1)
z
Feed button
: use for changing
MODE
status
z
Mode button
: use for changing
OPTION
status
[Example]
The defaults of the printer are:RS-232C/9600 BPS/8 DATA BIT/NO PARITY/ DENSITY LOW
If a user wants to modify the defaults with
RS-232C / 38400 BPS/7 DATA BIT/ EVEN PARITY / DENSITY HIGH
Press the
Mode Button
until the
Error Lamp
twinkles 5 times and release the button.
→
You will see the
Power Lamp
twinkles one time and
the
Error Lamp
twinkles 1 time.
→
This mode is RS-232C mode.
Press the
Feed button
one time, the
Power Lamp
twinkles twice and the
Error Lamp
winkles 4 times.
→
Press the
Mode Button
one time, the
Error Lamp
twinkles 5 times and press
the
Mode Button
one more time, the
Error Lamp
twinkles 6 times.
(The baud rate has set to 38,400 bps)
Press the
Feed Button
one time, the
Power Lamp
twinkles 3 times and
the
Error Lamp
twinkles 2 times.
→
Press the
Mode Button
one time, the
Error Lamp
twinkles one time.
(The Data Bit has set to 7 data bit.)
Press the
Feed Button
one time, the
Power Lamp
twinkles 4 times and
the
Error Lamp
twinkles 1 time.