background image

Woodway Engineering Ltd 

Lower Road, Barnacle

Coventry, CV7 9LD

United Kingdom

Tel:  +44 (0) 24  76 841750 

Fax:  +44 (0) 24  76 621796

[email protected]

www.woodwayengineering.com

I N S T A L L A T I O N   G U I D E

5

Keypad Programming

Programming Mode

To prevent accidental modification of the keypads set up, the special programming mode is only 

accessible via a special key press. Once active the warning LED will remain permanently lit, indicating 
the unit is not in normal operation.

To enter programming mode: Simultaneously hold channel 2, siren and reset for more than 2 

seconds. The battery voltage must be above 12.0 volts (engine running) to prevent the unit instantly 

going to sleep. When the keys have been pressed long enough the warning LED will light. Once 
programming is complete the same key press or an interruption to the power will make the unit 
revert to normal operation.

To reprogram the 999 activated channels follow 

the procedure above to put the handset into 
programming mode. When in programming mode, 

press the 999/arrival/reset switch and the blue LEDs 
in the switch will light. Press and hold the 999/arrival/

Modifying 999 and Arrival definitions

WARNING! 

Keypad programming should only be carried out with 

either the data wire to the receiver disconnected, or the receiver 
output connector removed to prevent unintentional operation of the 
vehicle equipment.

reset button until the blue part of the switch and the warning LED starts to flash. Whilst the LED is flashing, depress each key that is 
part of the intended program so that it is lit up. When finished, press the 999/arrival/reset button and the keypad will move into arrival 
programming mode. Move on to arrival programming or press 999/arrival/reset again to reset the keypad, then the keypad button 

press above can be performed to return to normal operation.

To reprogram the arrival activated channels follow the procedure above to put the handset into programming mode (you may already 

be in programming mode after setting the 999 settings). When in programming mode press the 999/arrival/reset switch twice until 
the red LEDs are lit then hold the 999/arrival/reset button until the red part of the switch and the warning LED starts to flash. Whilst 
the LED is flashing, depress each key that is part of the intended program so that it is lit up. When finished, press the 999/arrival/reset 
button and the sequence will be saved. You can now cycle through the 999/arrival/reset to check your selections are correct and 
make any adjustments necessary while still in programming mode.

Once programming is complete press the above programming key selection to return to normal operation. Alternatively, remove 
power from the handset.

Programming Other Options and Groups

Once in programming mode, holding various keys allows certain other 
parts of the system to be set-up.

REAR 

BAR 

MIC

CH 3 

CH 4 

PT

CH 5 

CH 6 

CH 7 

CH 8 

CH 9 

CH 10 

CH 11 

CH 12 

SIREN

RESET 

999/ARRIVAL 

FRONT 

BAR 

LED & LIGHT SENSOR 

Keypad button press to enter/exit programming mode 

 

S

Y

E

K

 

Y

E

K

 

YY

R

AR

A

TT

N

EN

E

M

M

O

O

M

M

 

E

M

M

U

L

O

V

 

A

P

 

U

L

O

V

 

A

P

 

T

ST

S

U

JU

J

D

AD

A

P

U

O

R

G

 

G

N

II

LL

LL

E

C

N E

C

N

A

C

 

F A

C

 

F

LL

EE

SS

  

2

 2

 

P

U

O

R

G

 

G

N

P

U

O

R

G

 

G

N

II

LL

LL

E

C

N E

C

N

A

C

 

F A

C

 

F

LL

EE

SS

  

1

 1

 

P

U

O

R

G

 

G

N

  

N

N

W

W

O

O

D

 

E D

 

E

M

M

U

L

O

V

U

L

O

V

 

P

U

 

E U

 

E

M

M

U

L

O

V

U

L

O

V

999 & ARRIVAL 

  

TT

L

UL

U

A

FA

F

E

D

 

Y

R

O

E

D

 

Y

R

O

T

CT

C

A

FA

F

SELECTIONS 

HIGHWAYS AGENCY MODE ACTIVATION TOGGLE 

 

E

L

G

G

O

 

E

L

G

G

O

T

 T

 

N

O

I N

O

I

T

A

V T

A

V

II

TT

C

A

 

9

9

9

 

L

A

C

A

 

9

9

9

 

L

A

N

N

R

ER

E

TT

X

EX

E

Summary of Contents for Opti-Din

Page 1: ...y Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com IN STALLATION GUIDE Opti Din H...

Page 2: ...s manual Disclaimer Important Installation and Safety Notes CAUTION Modules and connectors are not waterproof Install modules and cables in a dry location away from excessive heat humidity and any com...

Page 3: ...g The switch outputs from the Output Receiver Module interface directly with the low current control wiring of Woodway supplied light bars sirens and strobe power supply systems The outputs may be use...

Page 4: ...aggering the programmed switch activation When the battery supply falls below 12 volts providing no channels are selected the power down timer will start up After 20 minutes the unit will power down a...

Page 5: ...amming or press 999 arrival reset again to reset the keypad then the keypad button press above can be performed to return to normal operation To reprogram the arrival activated channels follow the pro...

Page 6: ...g mode press and hold the channel 6 selection key and repeat the operation above If more than one self cancelling group channel is incorporated as part of a 999 or arrival selection all channels will...

Page 7: ...s not flashing Communication fault Check data link connections are secure Check fuse Check voltage Check switch panel is plugged in Is the switch panel damaged or otherwise non functional High pitch w...

Page 8: ...CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 8 System Installation Wiring Diagrams 1 2 3 4 5 6 7 8 9 1...

Page 9: ...OUTPUT RECEIVER RELAY CONNECTIONS Socket SK3 Pin Wire Colour Function 1 Figure 5 2 3 White Orange Hands Free Plug P3 Pin Function Wire Colour 1 2 3 White Orange Hands Free Socket SK4 Pin Wire Colour...

Page 10: ...odway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 10 Note...

Page 11: ...odway Engineering Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com INSTALLATION GUIDE 11 Note...

Page 12: ...ring Ltd Lower Road Barnacle Coventry CV7 9LD United Kingdom Tel 44 0 24 76 841750 Fax 44 0 24 76 621796 sales woodwayengineering com www woodwayengineering com Made in the UK ISO 9001 2015 Certified...

Reviews: