39
Î
The teeth of the toothed belt underneath the slat-belt running surface have been pre-lubricated to
reduce noise during operation. The toothed belt can be cleaned and lubricant can be applied to its edges
once every six months or on an as needed basis.
x
Drive
belt
Î
As with the running surface toothed belt, the edges of the drive belt can also be lightly greased if it
"squeaks" audibly.
x
Inclination
system
Î
This is also lubricated at the factory. If the system requires lubrication again, apply a small amount of
lubricant to the lift mechanism shaft.
Caution – Possible danger of injury or damage
Please bear in mind that excess lubricant serves no purpose and only causes dirt and grease to
accumulate. Apply only extremely small amounts of lubricant, and use only the original lubricant
we have provided in the service kit.
The Prescribed Recurring Test Period
The prescribed recurring test period (according to BGV A4 (VBG 4) Accident prevention directive) averages for
treadmills 4 years (recommended is a test cycle of 1 year). This test may only be performed by an electrician or
through an authorized person approved by the manufacturer.
Electrical Testing According to VDE 0751
Grounding Conductor Resistance Measurement
<0.3 Ohm
Isolations Resistance Measurement
>2 MOhm
Backup Electrical Measurement
<1 mA
These measurements should be performed with approved gauges according to VDE 0751. A MTK “Technical
Measurement Control” according to § 11 is not prescribed by Woodway. If fluctuations of the display occur, the
measuring unit should be cleaned.
If a Technical Measurement Control is requested, a form from WOODWAY is available or it can be performed by
a WOODWAY approved Service Technician. The means and breadth of the Technical Measurement Control will
be defined by WOODWAY.