6
Trouble
Cause
Solution
The dehumidifier doesn’t
work
Is the power cord connected?
Connect the unit to a power outlet
Is the room temperature over 40°C or below
0°C?
Increase or decrease room tempe-
rature
The dehumidifier stops operating when the
set humidity is 2% higher than the ambient
humidity
To save energy, set the humidity level
higher
The unit doesn’t start
Is the filter blocked?
Clean the filter
Is the air inlet or air outlet jammed?
Clear the blockage
No air inlet
Is the filter blocked?
Clean the filter
Abnormal noise
Is the unit inclined?
Move the unit to a flat and solid
ground
Is the filter blocked?
Clean the filter
Trouble code: E1
When the display shows E1, there is a pro-
blem with temperature sensor or the connec-
tion wire is not properly fixed
Contact your retailer
Trouble code: E2
When the display shows E2, there is a pro-
blem with humidity sensor or the connection
wire is not properly fixed
Contact your retailer
Trouble code: E4
When the display shows E4, there is a pro-
blem with the water pump
Contact your retailer
Maximum working area
570 m
2
Recommended working area
10-315 m
2
Air flow
1000 m
3
/h
Capacity at 20ºC & 70% RH
33 litres
Capacity at 30ºC & 80% RH
88 litres
Power at 20°C & 70% RH
862 W
Power at 30°C & 80% RH
1260 W
Sound level
60 dB
Working interval temperature
0°C to +40°C
Fan speeds
1
Dims, LxWxH
635x500x800 mm
Weight
53 kg
Cooling media
R410 A (780 g)
IP rating
IP21 (X1)
Trouble shooting
If you are having trouble with your dehumidifier, please refer to below trouble shooting. If nothing of the below works,
please contact your retailer for servicing of your dehumidifier.
Technical data Wood’s WCD6HG
English
Summary of Contents for WCD6HG
Page 1: ...Wood s dehumidifierWCD6HG Users manual...
Page 2: ...Technical drawings Control panel Access the filter Attach the water hose Clean the filter...
Page 41: ......
Page 42: ......
Page 43: ......