PARTS AND ASSEMBLY

TROUBLESHOOTING GUIDE

PROBLEM

CAUSE

CORRECTION

Slow leakage

Cuts on sealing edge

Replace vacuum pad.

Dirt or lint inside pump

Wipe inside of handle with a soft cloth.  Check for contamination on 

U-cup or button.

Dry pump

Apply a light coating of plunger lube inside handle.

Scratches inside handle (between mid-

point and closed end)

Replace handle.

Release valve pad contamination

Open release valve and blow valve pad clean with air hose.

Contaminated pad face

Clean vacuum pad.

Severe leakage

Severe contamination

Clean plunger assembly and inside of handle.

Gouges or cuts on sealing edge

Replace vacuum pad.

Broken handle or release valve

Replace handle / release valve assembly.

Jammed or sluggish pump

Dry pump

Apply a light coating of plunger lube inside handle.

Obstructed valve stem

Remove obstruction (through suction inlet behind air filter).

Severe contamination

Clean plunger assembly and inside of handle.

Pad slips when attached

Contaminated load surface

Wipe surface clean. If necessary, wash and allow to dry.

Contaminated pad face

Clean vacuum pad.

Excessive glaze or wear on pad face

Replace vacuum pad (at least once every two years).

More than 10 strokes 

needed to apply

Any of the above

Perform general maintenance.

Dirt or lubricant on check valve

Remove, clean and reinstall plunger assembly, retainer and check 

valve as directed in Disassembly and Assembly sections (on facing 

page).

1  90151 

Handle / Release Valve Assembly

2  90154AM  Plunger Assembly

90158AM  Plunger Assembly, High Elevation (for N4100)

90524AM  Plunger Assembly, with Audio Alarm (WBP)

3  49486T 

Vacuum Pad, 8" [20 cm] Dia., Flat (G0695)

49478T 

Vacuum Pad, 8" [20 cm] Dia., Flat, Lipped,    

Low-Marking (VPFS8L)

49488T 

Vacuum Pad, 8" [20 cm] Dia., 

Textured Surface (G0695TS)

49506T 

Vacuum Pad, 9" [23 cm] Dia., Flat (G0725)

49520T 

Vacuum Pad, 9" [23 cm] Dia., Concave  

(VPCS9)

49586T 

Vacuum Pad, 10" [25 cm] Dia., Concave (G0750)

4  61151 

Check Valve Retainer

5  51100 

Check Valve

6  60024 

Air Filter

7  10002 

Handle Screws (6)

Red Line

Valve Release Lever

Not Shown

29330 

8" [20 cm] Case

29335 

8" [20 cm] Case, Grey

29338 

9" [23 cm] Case

29342 

10" [25 cm] Case

28504 

Plunger Lube

Summary of Contents for N4000

Page 1: ...WARNINGS To prevent liquid from contaminating the pump during cleaning hold the cup face down or cover the suction inlet in the filter recess For 8 20 cm pads be careful not to dampen the felt strip at the pad s edge Wipe all residue from the pad face and allow the cup to dry Then reinstall the air filter Inspecting and Testing the Cup for Leakage ToINSPECTTHESEALINGEDGESofthevacuumpadforroughness...

Page 2: ...hed Contaminated load surface Wipe surface clean If necessary wash and allow to dry Contaminated pad face Clean vacuum pad Excessive glaze or wear on pad face Replace vacuum pad at least once every two years More than 10 strokes needed to apply Any of the above Perform general maintenance Dirt or lubricant on check valve Remove clean and reinstall plunger assembly retainer and check valve as direc...

Page 3: ... cause leakage Scratches near the open end of the handle rarely present a problem Make sure that no lubricant remains inside the handle Drop the check valve inside the handle so that it lays flat against the closed end Using a dowel or other tool that will not scratch the sides of the handle push the retainer all the way into the handle to hold the check valve securely in place Attach Handle to Va...

Page 4: ...that could cause the cup to slip or to disengage prematurely such as contaminants cuts or scratches in the pad face or load surface applying the cup to porous materials or applying pressure against the pad edge Do not use the cup to lift when the red line is visible If the red line reappears frequently discontinue use and follow the instructions for general maintenance and testing Do not allow any...

Reviews: