Rev 11.3/1-17
32
MRTALPR4-DC: #35057
A
IR
F
ILTER
M
AINTENANCE
(for in-line filters)
Filter Function and Conditions Requiring Service
This air filter prevents solid particles from contaminating components in the vacuum system.
CAUTION: Examine air filter regularly and empty when necessary.
Open each filter regularly to determine whether liquid or other contaminants are trapped inside.
Remove any liquid or contaminants found. Clean or replace the filter element if it has an overall
dirty appearance, or if there is a noticeable increase in the time required to attain full vacuum
(see REPLACEMENT PARTS LIST).
Filter Service Procedures
1) Hold the filter case (1) and turn the
removable end (2) counter-clockwise
approximately 45° until it stops
moving.
2) Pull the end outward from the case
and remove the filter element (3).
Use an air hose or other suitable
means to remove any liquid or other
contaminants found inside the case.
Also make sure the seal (4) is not damaged.
3) Determine whether the filter element needs to be replaced (see Conditions Requiring Service
above).
4) Depending on the outcome of step 3, install a new element or reinstall the old element, as
shown in the illustration.
5) Align the 2 projections on the removable end with the grooves in the case, and insert the end
into the case. Push in and turn the end clockwise approximately 45° until it stops moving.
Make sure that the projections are completely visible through the windows (5) in the case.
6) Test the vacuum system, to make sure the air filter does not leak (see V
ACUUM
T
EST
preceding).