SAFETY INFORMATION
Before installing and using the
appliance, carefully read the supplied
instructions. The manufacturer is not
responsible if an incorrect installation
and use cause injuries and damages.
Always keep the instructions with the
appliance for future reference.
CHILDREN AND VULNERABLE
PEOPLE'S SAFETY
WARNING
Risk of injury or permanent
disability.
This appliance can be used by
children aged eight years and above,
persons with reduced physical,
sensory or mental capabilities, or
lack of experience and knowledge if
they have been given supervision or
instruction concerning the use of the
appliance safely and understand the
hazards involved. Do not let children
play with the appliance.
Children of less than three years
should be kept away unless
continuously supervised.
Keep all packaging away from
children. Cleaning and user
maintenance shall not be done by
children without supervision.
GENERAL SAFETY
This appliance is intended to be
used in households and similar
environments such as basements,
crawl spaces, staff kitchen areas
in shops, offices and other working
environments. Keep ventilation
openings clear of obstruction.
Other than those recommended
by the manufacturer, do not use
mechanical devices or other means
to accelerate the defrosting process.
The appliance shall not be stored in
a room where ignition sources are
operating continuously (open flames,
working gas appliance, operation
electric heater, etc.). Do not pierce
or burn. Be aware that refrigerants
may not have an odour. Do not use
water spray and steam to clean the
appliance. Clean the appliance with
a moist, soft cloth. Only use neutral
detergents. Do not use abrasive
products, abrasive cleaning pads,
solvents or metal objects. If the power
cord is damaged, it must be replaced
by the manufacturer, its authorized
Service Centre or similarly qualified
persons to avoid a hazard.
SAFETY INSTRUCTIONS
WARNING
Only a qualified person can install
this appliance.
Remove all packaging material. Do not
install or use a damaged appliance.
The appliance shall be installed,
operated and stored in a room with
a floor area larger than 4m². Strictly
follow the installation instruction
supplied with the appliance. Always
be careful when you move the
appliance because it is heavy. Always
wear safety gloves.
Make sure air can circulate around the
appliance. Wait at least 4 hours before
connecting the appliance to the power
outlet. This is to allow the oil to flow
back into the compressor. Do not
install the appliance close to radiators
or other heat sources. Do not install
the appliance in direct sunlight.
ELECTRICAL CONNECTION
WARNING
Risk of fire and electrical shock.
The appliance must be connected
to a grounded outlet. Ensure that
the electrical information on the
rating label is in accordance with
the power supply. If not, contact an
electrician. Always use a correctly
installed shockproof socket. Do not
use multi-plug adapters and extension
cables. Make sure not to cause
damage to the electrical components
(e.g. plug, cable). Contact the
authorized Service Centre or an
electrician to change the electrical
components. The cable must stay
below the level of the plug. Connect
the plug to the power socket only at
the end of the installation. Make sure
that there is access to the plug after
the installation. Do not pull the power
cable to disconnect the appliance.
Always unplug the power cable from
the plug only.
USE
WARNING
Risk of injury, burns, electrical shock
or fire.
Do not change the specification of
this appliance. Be careful not to cause
damage to the refrigerant circuit. It
contains propane (R290), a natural
gas with a high level of environmental
compatibility. This gas is flammable.
If damage occurs to the refrigerant
circuit, make sure that there are no
flames and sources of ignition in the
room. Ventilate the room. Do not put
flammable products or wet items with
flammable products near or on the
appliance.
DISPOSAL
WARNING
Risk of injury.
Disconnect the appliance from the
mains supply. Cut off the mains cable
and discard it. The refrigerant circuit
of this appliance is ozone-friendly.
Contact your local authority for
information on how to discard the
appliance correctly. Do not cause
damage to the part of the cooling unit
that is near the heat exchanger.
USE WOOD’S
DEHUMIDIFIER DSC95(P)
The Wood's DSC95(P) is a powerful and
sturdy dehumidifier suitable for crawl spaces,
basements, laundry rooms, and large areas.
Any reference to a pump throughout this
manual correlates to the DSC95P only, as the
DSC95 does not contain one.
Features:
• Automatic defrost for use in lower
temperatures, down to 2°C.
• Automatic pump (DSC95P only) for water
drainage to a sewer.
• Duct connection for better distribution of the
dried air.
• Automatic restart with memory function after a
power cut.
• Easy to use controls.
• Efficient air filter.
WORKINGS OF YOUR DEHUMIDIFIER
The Wood’s DSC95(P) is a compressor-driven
dehumidifier. As the air is circulated through the
room and drawn through the dehumidifier by the
fan, the air passes over the cooling/drying battery.
The coils cool down the air led through, which
causes its water content to condensate on the coils.
The condensate is collected in a tray underneath
the cooling battery, led to the pump (DSC95P only),
and drained via an external hose. The remaining
dry air is exhausted throughout the room.
As the dehumidifier condensates the water
vapour, heat energy is released. That is why a
compressor dehumidifier will exhaust warm, dry
air, which is extra beneficial for drying clothes,
laundry, wood, etc.
A compressor dehumidifier is the most energy-
efficient way to remove excess moisture and foul
odour. To achieve safe and reliable protection against
mould and moisture damage, it is recommended to
keep the relative humidity level around 50%.
PRODUCT OVERVIEW
See pages 2–3 for image product overview.
A
DEHUMIDIFIER DSC95(P)
1.
Control panel
2. Nose clamp (for external drain
hose, not included)
3. Hose nozzle
4. Modular cable (control panel)
5. Air exhaust bracket
6. Air exhaust hose
B
DRAIN HOSE ASSEMBLY
C
PUMP FILTER
1.
Garden hose nozzle
2. Pump filter (DSC95P only)
3. Drainage pump (DSC95P only)
D
AIR FILTER
E
CONTROL PANEL
CONTROL PANEL FUNCTION
DESCRIPTION
The Wood's DSC95(P) are equipped with an
intuitive wired remote-control panel for simple
and convenient use. If the 2 m wire supplied with
the unit is too short, it can be replaced by an
RJ11/RJ12 modular cable with male connectors
at both ends. Please note that the length of the
cable should not exceed 10 m.
Note that the control panel powers down to
idle mode 20 seconds after connection of mains
voltage or after the last input. It is revived by
touching the area where the function keys are
located. All keystrokes are confirmed with a beep.
FUNCTION KEYS
1.
ON/OFF: Switches the dehumidifier on and
off. In off mode, the energy consumption
equals 0.5 W.
2. Setting of the desired humidity: Only
active in program modes “Normal” and
“Fan”.
A desired humidity can be set between 35
- 75% in steps of 1 percentage point. The
set value is first displayed fixed and then
flashing before the actual value reappears.
3. Mode selection: Selection of the operating
program; refer to points 12. - 14.
4. Fan speed: The fan's speed in "Normal"
and "Fan" mode may be set at low or high
speed. Switching between the speeds
takes place with a few seconds delay.
ALARMS / INFORMATION
5.
Defrost: If necessary, the cooling circuit
is defrosted automatically, whereby the
compressor is switched off, and only the
fan is in operation. The symbol goes out
when the dehumidification process is
restarted.
6. Too high ambient temperature: If the
ambient temperature exceeds 35° C, the
dehumidification process shuts off and
resumes automatically when the ambient
temperature falls below 35° C. The symbol
is lit as long as the temperature is 35° C or
higher.
7.
Low room temperature: If the ambient
temperature falls below 2° C, the
dehumidification process shuts off and
resumes automatically when the ambient
temperature rises above 2° C. The symbol
is lit as long as the temperature is 2° C or
lower.
8. Pump malfunction (DSC95P only): If a
pump malfunction occurs, an audible signal
is activated for 20 seconds, and the symbol
is lit. Refer to the "Problem/Remedy" table.
9.
Room temperature: Displays the detected
ambient temperature.
10. Fan speed: Fan and dashes indicate high
speed, and only the fan indicates low
speed.
11. Relative humidity: Shows current and
desired target values. The latter is in
connection with target value setting.
OPERATING MODES
12. Fan Mode (FAN) – Continuous air
circulation even if the humidity target value
is reached.
13. Comfort mode (EASY) - The dehumidifier
aims for 50% relative humidity with the fan
set to low speed. When the target value is
reached, the compressor and fan shut off
and restarts if the humidity rises above 50%.
14. Normal Mode (NORMAL) – Used to set the
target value for humidity and fan speed
manually. When the set target value is
reached, the compressor and fan shut off
and restarts if the humidity rises above the
target value.
15. Lock function - Used to prevent the
settings from unintentionally being
changed. The lock function is activated
by simultaneously operating the FAN and
MODE keys for 3 seconds. Disabling the
lock function is done in the same way.
Safety Instructions
Product Description
Refer operator's manual.
Read technical manual.
Read the operator's
manual.
FLAMMABLE MATERIAL.
This appliance contains R290/