GB
15
Operating Instructions
FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS
PROBLEM
CAUSE
REMEDY
Unit does not start
when pressing on/off
button
Not plugged in / Plug or socket is damaged.
Plug in or replace the power or socket.
Fuse broken
Replace the fuse (3.15A/250AC)
Room temperature is lower than the setting temperature.
(Cooling mode)
Reset the temperature
Not cool enough
The doors or windows are not closed.
Make sure all the windows and doors are closed.
There are heat sources inside the room.
Remove the heat sources if possible
Exhaust air hose is not connected or blocked.
Connect or clean the exhaust air hose.
Temperature setting is too high.
Reset the temperature
Air inlet is blocked.
Clean the air inlet.
High noise level
The ground is not level or not flat enough
Place the unit on a flat, level ground if possible
The sound comes from the flowing of the refrigerant inside the
air conditioner
It is normal.
If you are having trouble with your dehumidifier, please refer to below trouble shooting. If nothing of the below
works, please contact your retailer for servicing of your Air Conditioner.
Error Codes
CAUSE
REMEDY
E2 Code
Room temperature sensor failed or is damaged.
Replace room temperature sensor
E3 Code
Evaporator temperature sensor failed.
Replace evaporator temperature sensor
E4 Code
Water tank full
Please empty the water tank.