Wood’s AC Palermo Pro 18K Operating Instructions Manual Download Page 14

GB

14

Operating Instructions

a desired room temperature.

(15°C - 31°C)

-Press the “Fan Speed” button to

select wind speed.

 

     

6.   Timer operation

a) Press the “Timer” button to set 

Automatic Off time while the unit is 

running.

b) Press “Timer” button to set Automatic 

off time while the unit is ready.

c) The time can be adjusable within a 

range of 1 hour to 24 hours. Press the 
temp up (

+

) or temp down (

-

) button to 

increase or decrease the time 1 hour by 

pressing once.

7.   Operation

a) The    operation is effective when the 

unit is under   mode.

b) Press the   button in   mode, then the 

unit will work under sleep mode and the 

up centrifugal fan will turn to low speed 

automaticlly. The set temperature will 

increase 1°C After one hour and increse 

2°C after two hours. After six hours, the 

unit will stop running.

8.   Operation

a) when the swing button is activated, 

the swing blade swings up and down 

automaticlly. If you want to stop, press the 

button again.

Internal Tank Water Full Alarm

Function

The inner water tank in the airconditioner

has one water level safety

switches, it controls the water level.

When water level reaches an

anticipated height, the water full

indicator lights up. When the water is

full, please remove the rubber

blockage from the drainage hole at

the bottom of unit, and drain all water

outside.

Continuous Drainage

-When you plan to leave this unit

unused for a long time, please

remove the rubber blockage from the

drainage hole at the bottom of unit,

and drain all water outside.

-You can use the continuous drainage

with a drainage hose connected to the

bottom drain hole, when the unit

working at the HEAT mode.

-The continuous drainage is not need

to be applied when the unit working at

the COOL or DEHUMIDIFY mode.

The unit can evaporate the

condensate water automatically by

the splash motor. Make sure the

drainage holes are stemmed well.

-If water splash motor is damaged,

continuous drainage can be used. 

To connect the drain hose to the

bottom drain hole, the unit can also

work well.

-If splash motor is damaged,

intermittent drainage can also be

used. Under this condition, when the

water full indicator lights up, please

connect a drain hose to the bottom

drainage hole, then all the water in the

water tank will be drained outside. The

unit can also work well.

 

Maintenance

Clean theunit with a soft moist cloth. Do 

not use solvents or strong cleaners as this 

might damage the surface of the unit. 

Service 

 

If the Air Conditioner requires servicing,

you must first contact your local retailer.

Proof of purchase is required for all

warranty claims. 

 

Storage instructions  

 

End of Season Storage

1) Screw off the drain cover and pull out

the stopper to drain condensate water

completely.

2) Keep unit running in fan mode for half

day to dry inside of unit completely to

prevent from going moldy.

3) Turn off the unit, pull out plug then

wrap the power cord around the wire-

winding pillar, insert the plug into the

universal fixing hole at the back panel

of the unit, install the water stopper and

drain cover.

4) Remove the heat exhaust hose 

assembly,

clean and keep it properly.

Notes:

Hold the exhaust hose assembly with

both hands when removal.

Push the fasteners aside on exhaust air

outlet using your thumbs, then pull out

exhaust hose assembly.

5) Pack the air-conditioner properly with

soft plastic bag and put it in dry place

with appropriate dust-proof measures,

and keep the unit away from children.

6) Take out the batteries from the remote

control and keep it properly.

Note:

Assure the unit is stored in a dry place.

All accessories of the unit shall be 

protected

together properly

Power cord holder and universal socket

can well protect the power cord.

High position of exhaust air outlet, easy

assembly and venting quickly.

Intelligent, environmental-friendly and

energy saving with self-evaporative

cooling system.

24-hour Timer function, unique on/off

reminding music.

3-minute delay re-starting protection to

compressor and other multiple protection

functions.

FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS

Summary of Contents for AC Palermo Pro 18K

Page 1: ...NSTRUCTIONS FOR AC Palermo Pro 18K Manual WAC1810G Operating Instructions GB Betjeningsvejledning DK Manual de instrucciones ES Lieto anas instrukcija LV Bedienungsanleitung DE Instrukcja obs ugi PL B...

Page 2: ...ntacting our Authorised Service Centre ensure that you have the following data available Model number receipt and serial number The refrigerant used in portable air conditioner is the environmentally...

Page 3: ...ING INSTRUCTIONS English Swedish Norwegian Danish German French Spanish Dutch Polish Romanian Finnish Lithuanian Latvian Estonian Greek Icelandic 12 19 20 27 28 35 36 43 44 51 52 59 60 67 68 75 76 83...

Page 4: ...GB 4 Operating Instructions A B 1 6 2 3 4 5...

Page 5: ...GB 5 Operating Instructions D C PRODUCT DESCRIPTION 5 2 1 3 4 5 6...

Page 6: ...GB 6 Operating Instructions PRODUCT DESCRIPTION E F G 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17...

Page 7: ...GB 7 Operating Instructions PRODUCT DESCRIPTION H I J...

Page 8: ...GB 8 Operating Instructions PRODUCT DESCRIPTION K L M...

Page 9: ...a flammable refrigerant Refer to this manual for safety information Read technical manual Read operators manual SAFETY INFORMATION Before the installation and use of the appliance carefully read the s...

Page 10: ...t Do not use multi plug adapters and extension cables Make sure not to cause damage to the electrical components e g mains plug mains cable Contact the Authorised Service Centre or an electrician to c...

Page 11: ...conditioner must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room The effectiveness of the air Conditioner depends on the temperature...

Page 12: ...or claning H 1 Twist both ends of the exhaust hose into the Hose Connector I 1 Drain Plug K 1 Introduction to Exhaust Hose Installation L 1 Make sure that there is no kinks in the exhaust hose M 1 Lif...

Page 13: ...nit from any electric supply outlet 2 Do not use gasoline or other chemicals to clean the unit 3 Do not wash the unit directly 4 If the conditioner is damaged please contact the dealer or repair shop...

Page 14: ...ct the drain hose to the bottom drain hole the unit can also work well If splash motor is damaged intermittent drainage can also be used Under this condition when the water full indicator lights up pl...

Page 15: ...he exhaust air hose Temperature setting is too high Reset the temperature Air inlet is blocked Clean the air inlet High noise level The ground is not level or not flat enough Place the unit on a flat...

Page 16: ...w 950 m3 h 950 m3 h Energy class A A Dehumidification 60 L 24h 64 8 L 24h Temperature setting 17 30 C 17 30 C Working temperatur 16 43 C 16 43 C EER 2 6 2 6 Drain Hose Length 1 0 m 1 0 m Hose Diameter...

Reviews: