-9-
5. ADJUSTMENT AND OPERATION
WARNING
Handle the tools with protective gloves.
5.2 TILTING THE TABLE
- Loosen the lock handle A on the table trunnion.
- Turn the table tilting knob B to adjust the table to the
desired angle. Use the angle indicator scale on the
trunnion bracket to find the desired angle.
- Retighten the lock handle to secure the table.
Fig.5.1
5.1 SETTING TABLE SQUARE TO BLADE
The table may be set at 90degree to the blade by
adjusting the table stop screw under the table. The table
stop screw rests on the top of the lower wheel bandwheel
housing. By first slackening the locking nut A and then
adjusting the screw B, the table can be set correctly.
Retighten the locking nut A making sure that the setting is
maintained.
B
A
Fig.5.2
A
B
Fig.5.3
5.3 TRACKING BLADE AND ADJUSTING
BLADE TENSION
- Firstly, make sure the upper and lower blade guides
are adjusted away from the blade and the tension scale
reading corresponds to the width blade you are using.
- Then loosen the lock lever A by turning it
counterclockwise and turn the blade tracking knob B
clockwise/conterclockwise while turning the upper wheel
by hand at least three rotations until the blade tracks
centered on the wheel. Finally, tighten the lock lever and
close the doors.
- To loosen the tension of the blade, turn the blade tension
handwheel C counterclockwise.
- To tighten the tension of the blade, turn the blade
tension handwhee.
- Tesnion the blade until the tension readings corresponds
to the width of blade you are using.
A
B
C
Quick Release
Lever