background image

R

R

R

GE 

R

WOODBRIDGE  W

R

GE 

R

WOODBRIDGE  W

GE

WOODBRIDGE W

www.woodbridgebath.com

20200623 REV. 1 

R

WOODBRIDGE 

INSTALLATION   AND   CARE   GUIDE

ELONGATED TOILET :  T0033/B0933

•  2015 Uniform Plumbing Code    

( UPC )

•  2018 International Plumbing Code    

( IPC )

•  2018 International Residential Code    

( IPC )

•  CSA  B45.5 / IAPMO  Z124-2017- Plastic Plumbing Fixtures    

®

®

®

Compliance with the following codes & standard:

PREFERED
EDUCATION
PROVIDER

LISTED

TM

ICC

SCC  Accredited

CB-P/S  

OCPS

Accrédité 

CCN

ANSI

ACCREDITED

                ISO/IEC 17065     
     Product Certification Body
                    #1000

Customer Service Phone: 562-229-0088. (Monday - Friday 9 AM - 5 PM Pacific Time)

    Or Email: 

[email protected]

Summary of Contents for B0933

Page 1: ...tional Plumbing Code IPC 2018 International Residential Code IPC CSA B45 5 IAPMO Z124 2017 Plastic Plumbing Fixtures Compliance with the following codes standard PREFERED EDUCATION PROVIDER LISTED TM ICC SCC Accredited CB P S OCPS Accrédité CCN ANSI ACCREDITED ISO IEC 17065 Product Certification Body 1000 Customer Service Phone 562 229 0088 Monday Friday 9 AM 5 PM Pacific Time Or Email help woodbr...

Page 2: ...T BE OBSERVED FOR SAFE INSTALLATION We reserves the right to change update modify alter redesign this manual product or its policies without prior noধce We shall not be liable for any injuries or property damages in connection with this product during installation or use of this product This products must be installed by a fully insured and licensed plumber only Installation of any our product by ...

Page 3: ...ficaধons Configuraধons are subject to change without noধce Pls measure toilet on site before installaধon Please note that installer s must be cerধfy or warranty will be voided Measurements herein supersede all others published prior to purblicaধon date shown below 12 Rough in Standard 15 1 2 28 1 4 6 1 2 1 1 8 18 14 1 4 26 3 4 10 5 8 15 14 ...

Page 4: ...ers published prior to purblicaধon date shown below 12 Rough in Standard Wall Floor 12 Rough in Standard Side View Side View Back View Wall Floor Flush GPF amount is factory set No addiধonal adjustment is required Tank Top View Inside Half Flush 1GPF Adjust the water level in the toilet s tank if neccessary by rotaধng the adjustment screw to increase or decrease a level of water in the toilet s ta...

Page 5: ...ugh the holes and align bolts horizontaly See Figure 2 Figure 3 INSTALL WAX RING Important safety glasses must be worn by the installer and all bystanders Cover the floor with a soft close blanket Carefully turn the toilet on it s side or upside down on the blanket with assistance of a second person Install wax ring over the horn discharge located on the bottom of the toilet s bowl See Figure 3 No...

Page 6: ...for water damage or flood caused due to use of this product Under no circumstances We shall not be liable for any and all fees cost of installation reinstallation removal subsequent damage or transportation in case of the product defect Figure 6 INSTALL NEW TOILET Step 1 Lift and carefully put the toilet over the closet flange so the closet bolts can go through the mounting holes in the toilet s b...

Page 7: ... toilet seat and cover Clip on the toilet seat and cover Aligh the toilet seat and cover with ceramic Take off the toilet seat and cover by pressing both pushbuttons Insert the hinges into the toilet Tighten the screws of the hinges Untighten the screws a bit by turn ing them 90 right Seat and cover Hinge set ELONGATED TOILET ...

Page 8: ...sh button and lock the nut to make it well fixed in the tank The distance between the rod tail and valve push button must be 1 2mm Rotate the valve clockwise to adjust its position inside of the toilet s tank Install the sealing gasket Put the refill tube into the white cap hole firmly The refill tube can t be lower than the watersealing level If the rod is too short please re adjust it outward ro...

Page 9: ...s not have any damaged or missing parts 1 Press buckle and unscrew 2 Pull the valve upwards or press down to desired height 3 Unscrew the valve body and fasten the buckle Rotating screw rise or lower the water level to adjust water level to suitable position water volume will gradually increase when the adjuster is moved upward from the bottom 1 PREPARATION 2 WATER LEVEL ADJUSTMENT Press and unscr...

Page 10: ...is clogged due to dirty water 4 Improper refill hose installation 1 Turn on inlet valve switch 2 Adjust inlet valve position 3 Clean the filter screen 4 Install refill hose correctly see diagram on the right Carefully take out the filter from inlet by using pliers Use water to wash and clean the filter and adapter from any debris Re install the filter and re connect the water supply line FILL VALV...

Reviews: