background image

Cascade Gas-Fired Rotisserie 

Installation and Operation Manual

 

PG 

OF

 28

M0049.08  MARCH 2018

An ongoing program of product improvement may 
require us to change specifications without notice. 

WOOD STONE CORPORATION

1801 W. Bakerview Rd.
Bellingham, WA 98226  USA

TOLL FREE

 800.988.8103

TEL

 360.650.1111

FAX

 360.650.1166

E-MAIL

 

[email protected]

woodstone-corp.com

CASCADE GAS-FIRED ROTISSERIE

INSTALLATION AND OPERATION MANUAL FOR THE 

WOOD STONE CASCADE ROTISSERIE

STONE FIRED COOKING EQUIPMENT 

WS-GFR-6 (SIX SPIT)

AND WS-GFR-10 (TEN SPIT) MODELS

GAS-FIRED ROTISSERIE

ADDITIONAL COPIES AVAILABLE UPON REQUEST

WS-GFR-6 shown with left side 

drive and Air Block Panel

Summary of Contents for CASCADE WS-GFR-10

Page 1: ... www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA CASCADE Rotisserie Gas Fired Rotisserie Six and Ten Spit Models CASCADE WS GFR 6 CASCADE WS GFR 10 DOC NO M0049 08 REVISED MARCH 2018 Installation and Operation Manual ...

Page 2: ...00 988 8103 TEL 360 650 1111 FAX 360 650 1166 E MAIL info woodstone corp com woodstone corp com TABLE OF CONTENTS TABLE OF CONTENTS Cascade Gas Fired Rotisserie 3 Cautions Warnings 4 Specifications 6 Receiving the Rotisserie 7 Installation 8 Clearances Venting 9 Utility Specifications 10 Utility Connections 12 Controllers 13 Daily Operation 14 Optional Accessories 17 Preventive Maintenance 19 ELEC...

Page 3: ... Rd Bellingham WA 98226 USA TOLL FREE 800 988 8103 TEL 360 650 1111 FAX 360 650 1166 E MAIL info woodstone corp com woodstone corp com CASCADE GAS FIRED ROTISSERIE INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CASCADE ROTISSERIE STONE FIRED COOKING EQUIPMENT WS GFR 6 SIX SPIT AND WS GFR 10 TEN SPIT MODELS GAS FIRED ROTISSERIE ADDITIONAL COPIES AVAILABLE UPON REQUEST WS GFR 6 shown with left...

Page 4: ...allation in your area RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone corp com For prompt responses to service maintenance questions call us at 1 800 988 8103 WARNING Improper installation adjustment alteration service or maintenance can result in property damage injury or death Read the installation operation and maintenance instructions thoroughly before ins...

Page 5: ...NCES AIR SPACES TO COMBUSTIBLE MATERIALS IT IS OF THE UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS SAVE THE INSTRUCTIONS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts IN THE EVENT OF A POWER FAILURE NO ATTEMPT SHOULD BE MADE TO OPERATE THIS APPLIANCE WARNING Do not pack req...

Page 6: ...atural Gas NG OR 185 000 BTU hr Propane LP Maximum gas inlet pressure 1 2 psi 14 inches W C Electrical 120 VAC 5 A 50 60 Hz NEMA 5 15 plug 240 VAC 2 A 50 60 Hz plug by others Water Inlet 1 4 FNPT Drain 1 1 2 outlet tube All utility connections made on bottom of the unit Refer to data plate when installing Venting The Cascade Rotisserie must be vented using a Listed Type 1 exhaust hood or one const...

Page 7: ... rear of the rotisserie Adjust the forks so that they are just narrow enough to fit within the stainless angles on the bottom of the unit Remove the crating Do not rest the rotisserie on the stainless angles If the rotisserie must be set down before the legs are mounted support the unit using appropriately arranged blocks which extend beyond the sides LEG CASTER POSITIONING ASSEMBLY The legs caste...

Page 8: ...his appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 or CSA 6 16 and a quick disconnect device complying with ANSI Z21 41 or CSA 6 9 It must also be installed with restraining means to guard against transmission of strain to the connector as specified in the appliance manufacturer s instructions ATTENTION INSTALLER EQU...

Page 9: ...lation air VENTING The Wood Stone Cascade Gas Fired Rotisserie must be vented using a Listed Type 1 exhaust hood or one constructed in accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations NFPA 96 and all relevant local and national codes and in a manner acceptable to the authority having jurisdiction It is never appropriate to use B vent in any ...

Page 10: ... recommends that the rotisserie be equipped with a manual individual shutoff valve located between the oven and the main gas supply and that this shutoff valve supplied by others be left readily accessible Wood Stone also recommends that inspection and maintenance of the burners and gas piping connections of this appliance be performed at regularly scheduled intervals and only by professional gas ...

Page 11: ...y sized flexible connector approved for this application When using a flexible connector make sure that its design does not present any reduction in pipe diameter or other restriction Oven issues caused by improper pipe sizing improper shut off valves restrictive connectors or any other deficiency in the gas supply design or installation will not be covered under the oven warranty GAS CODE LIMITAT...

Page 12: ... attached to the rotisserie at the IEC connection on the bottom of the unit with a NEMA 5 15 plug COLD WATER INLET Supply an incoming cold water line fitted with a 1 4 NPT male connector DRAIN TO FLOOR SINK GREASE TRAP A 1 1 2 drain outlet tube at the bottom of the rotisserie is provided This outlet must be connected to an indirect waste pipe and discharge by means of an air gap in accordance with...

Page 13: ...ORE ATTEMPTING TO RELIGHT THE BURNERS GREEN Starts rotisserie drum when rear doors are open depressing the button will jog the drum YELLOW Lights both burners rotisserie drum must be activated before burners will light Water Valve Knob Gas Throttle Knob BLACK Rotisserie drum Speed Control Knob RED Stops both burners and rotisserie drum GREEN Starts rotisserie drum when rear doors are open depressi...

Page 14: ...top When loading make certain product does not hit the back wall or the optional smoker box as the drum turns Note Drum rotates from the bottom up NEVER ATTEMPT TO PLACE OR REMOVE SPITS WHEN THE ROTISSERIE DRUM IS MOVING BURNERS WON T TURN ON IF DRUM IS NOT TURNING LOADING THE SPITS The spits can only be inserted into the rotisserie drive one way When loading the rotisserie make sure the load is e...

Page 15: ...OPPING THE DRUM ROTATION AND BURNERS There are four ways to stop the drum rotation and burners with standard back door models 1 Push the bump bar style shut off on the front of the rotisserie all models 2 Push the RED button on the Front Controller all models 3 Push the RED button on the Rear Controller on standard back door models 4 Open the rear door if equipped TO RESTART THE ROTISSERIE BURNERS...

Page 16: ...emblies to avoid accidental damage Never spray water onto or around the burners or into either of the side compartments on the rotisserie CLEANING THE ROTISSERIE CABINET EXTERIOR All exposed surfaces of the rotisserie should be wiped clean daily using an approved mild cleaning solution Stubborn residues may be removed using a non metallic scouring pad When scouring stainless steel scrub with the g...

Page 17: ...shell Basket spit is constructed of heavy gauge stainless steel and conveniently adjusts to hold a variety of products ranging from fresh vegetables to two entire prime ribs Stainless steel screens are also available to help secure smaller items Includes Chain Assembly For Clamshell Basket locking mechanism D FISH AND VEGETABLE SCREEN The 26 x 16 Fish And Vegetable Screen inserted into the Clamshe...

Page 18: ... upright The cart facilitates spit loading and provides spit storage J GFR SMOKER TRAY The Smoker Tray is a perforated stainless steel box for use with GFR gas fired rotisserie to help influence flavor It accommodates approximately 3 5 lbs of well soaked wood pieces and partially ignited charcoal to create smoke Wood and charcoal can be replenished during the cook cycle to maintain smoke K SPIT FO...

Page 19: ...ed and requires no additional maintenance SPUR GEAR BUSHING Check the spur gear bushings for signs of binding or lateral movement where the gear shank passes through the drive end drum The gear should rotate in the Rulon inner bushing If the gear and Rulon bushing are rotating in the drum sleeve instead remove the gears and Rulon bushings clean and refit Do not lubricate the bushings or gears To r...

Page 20: ...de Gas Fired Rotisserie Installation and Operation Manual ELECTRICAL DIAGRAMS 120VAC These diagrams can also be found affixed to the inside of the drive side service panel of the rotisserie Used on all models with dual controls no broiler ...

Page 21: ...M0049 08 MARCH 2018 Cascade Gas Fired Rotisserie Installation and Operation Manual ELECTRICAL DIAGRAMS 120VAC These diagrams can also be found affixed to the inside of the drive side service panel of the rotisserie ...

Page 22: ...de Gas Fired Rotisserie Installation and Operation Manual ELECTRICAL DIAGRAMS 240VAC These diagrams can also be found affixed to the inside of the drive side service panel of the rotisserie Used on all models with dual controls no broiler ...

Page 23: ...M0049 08 MARCH 2018 Cascade Gas Fired Rotisserie Installation and Operation Manual ELECTRICAL DIAGRAMS 240VAC These diagrams can also be found affixed to the inside of the drive side service panel of the rotisserie ...

Page 24: ...r the options included with the unit being serviced This determines which Control Panels are used R2 R1 R1 Door Switch Violet 24 VAC Red 120 VAC C Bump Bar R2 R1 MM23002D R1 R2 Pin Assignment 12 9 13 14 4 1 8 5 8 14 13 1a 12 1 9 9 5 5 1 1 MM23002D 3 S3 S2 S1 A2 L1 L2 115 230 115 A1 180 90 WS GFR Electrical Line Diagram Cascade Gas Fired Rotisserie T1 L2 C C 1 1a 2 3 4 5 10 12 12 Wht yel Blk gry Gr...

Page 25: ...d fired equipment configurations in the event that pressed log products of any type have been burned in the equipment 9 In coal fired oven configurations in the event any type of coal other than anthracite coal fuel has been used 10 Damage resulting from the use of chemical cleaning products in the oven as well as any damage from liquids or chemicals including water being poured or sprayed into th...

Page 26: ...PG 26 OF 28 M0049 08 MARCH 2018 This page left intentionally blank ...

Page 27: ...PG 27 OF 28 M0049 08 MARCH 2018 This page left intentionally blank ...

Page 28: ...Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 www woodstone corp com WOOD STONE CORPORATION 1801 W Bakerview Rd Bellingham WA 98226 USA An ongoing program of product improvement may require us to change specifications without notice ...