Maintenance
Safety Devices Inspection
EGdoc013119
5-8
5
5.5
Safety Devices Inspection
WB2000 – Safety Devices Inspection
Safety devices on the WB2000 machine which must be checked before every shift:
E-STOP button and its circuit
Control circuits with the E-STOP button pressed
Blade cover safety switch #1 and its circuit
Blade cover safety switch #2 and its circuit
Motor brake and its circuit
1. E-STOP button and its circuit inspection
Turn on the blade motor;
Press the E-STOP button located on the left side of the control box. The blade motor should be stopped.
Pressing the START button should not start the motor until the E-STOP button is released.
2. Inspection of the control circuits with the E-STOP button pressed
Turn on the blade motor;
Press the E-STOP button located on the left side of the control box. The blade motor should be stopped.
With the E-STOP button pressed, try to move the saw head up and down using the switch and the Setworks
buttons, and forward/backward using the power feed switch. Both systems should not start.
With the E-STOP button pressed, try to start the debarker blade motor and move the debarker arm in and
out. The debarker should not work.
With the E-STOP button pressed, try to move the blade guide arm in and out. The blade guide arm should
not work.
With the E-STOP button pressed, try to start the board return system. The board return system should not
work.
3. Blade cover safety switch #1 and its circuit inspection
Turn on the blade motor;
Open the blade housing cover #1;
The blade motor should be stopped;
Try to start the motor. The blade motor should remain stopped;
Close the blade housing cover #1;