MAINTENANCE
Safety Devices Inspection
4
4-6
doc052521
MAINTENANCE
4.6
Safety Devices Inspection
MP180E7S Multi-Planer – Safety Devices Inspection
Safety devices on the machine which must be checked before every shift:
E-STOP button and its circuit inspection.
1. E-STOP buttons and their circuits inspection
Use “I” buttons to start the cutter and feed rollers. The motors should start.
Press the E-STOP button No. 1 located on the control box. All motors should be stopped.
Pressing the “I” buttons should not start the motor until the E-STOP button is released.
Release E-STOP button Bo. 1. Use “I” buttons to start the cutter and feed rollers. The motors
should start.
Press the E-STOP button No. 2 located on the machine housing. All motors should be stopped.
Pressing the “I” buttons should not start the motor until the E-STOP button is released.
2. Side cutter cover safety switch and its circuit inspection
CAUTION!
Use extreme caution when opening the cutter housing
cover if the top and side cutters are working (to inspect the safety
devices).
Use “I” buttons to start the top and side cutter and next the feed rollers. The motors should
start.
Be sure the emergency stop button is released.
Open the side cutter housing cover.
All motors should be stopped.
Pressing any of “I” buttons should not start the motors.
Close the cutter housing cover.
The motors should remain stopped until they are restarted with any of “I” buttons.