Operation
Machine Operation
Operation
SISdoc112009
2-5
2
2.3
Machine Operation
1.
Clean the blade and deburr before putting in the toothsetter. Otherwise, sap buildup on
the blade or tooth will give false set readings. Metal burrs created by sharpening will also
cause false readings.
2.
Mount the blade in the toothsetter. Place blade between the clamping plates and on the
three guide assemblies. Use the weld as a reference point for starting.
See Figure 2-3.
Position the tooth in front of the sensor pin so its edge is approximately
.0625" (1.6mm) away from the edge of the pusher pin.
3.
Turn the ON/OFF switch to the ON position.
4.
Now all of the adjustments have been made. Push START to begin the setting operation.
All values will remain as set.
5.
Toothsetter works automatically.
To adjust the pusher adjustment knobs, push the CLAMP button. Tooth bend value will
appear on the display. This value should be between upper and lower set limit. If, it will be
smaller, turn the pusher adjustment knob to adjust as small value as possible. Next, hold
down the Manual Bend button and observe display readings. Increase tooth tilt by
adjusting the knob.
If the unbended tooth value is between upper and lower set limit, push the START button.
Tooth will be setting automatically.
(Repeated bending of the same tooth can occur. During the setting operation, tooth bend
value should be corrected by using the pusher adjustment knob.)
FIG. 2-3
Edge of tooth
approx. .0625” (1.6mm)
from edge of pusher pin
Si0009