![Wood-mizer 096009 Safety, Operation, Maintenance & Parts Manual Download Page 13](http://html1.mh-extra.com/html/wood-mizer/096009/096009_safety-operation-maintenance-and-parts-manual_994530013.webp)
General Information & Safety
System Parameters
General Information & Safety
SISdoc112009
1-10
1
1.11 System Parameters
Press the MENU button once. Push the DOWN arrow button to find the SYSTEMS
PARAMETERS menu. Press ENTER to see parameters needed to be set.
When selected, the following parameters can be set:
Max Tooth Set Errors
1
-
push the ENTER button to enter the "Max Set Errors #" param-
eter. Use the UP and DOWN buttons to adjust the maximum number of teeth that can be
set incorrectly in the setting process. When the number of errors is exceeded the setting
process will be stopped. The "Error -- Bld !! Tooth Set #" message appears. The # mark is
the current tooth set.
NOTE:
To decrease set, bend the tooth back with the slot in the cor-
rection tool provided. Press the green Start/Resume button to cancel the error. Push the
F3 Manual Bend button to allow the setter to set the tooth again. To add set, press the F3
Manual Bend button.
Dpy Imperial/MM -
when selected, the "Standard Selected" appears, followed by the cur-
rent selection: Imperial or Metric. Use the UP and DOWN arrows to switch the units of
measure. Press ENTER to confirm.
NOTE:
Always turn the setter off after changing the
units of measure. Turn the setter on to use new units of measure.
1. Number of the straightening teeth cylinder cycles. It allows to limit too many cylinders hits (it is
used when the teeth is broken, damaged or it is hard to set it.)