The secondary ash pan is located under the main combustion chamber. This needs to be
emptied less frequently.
Secondary ash pan area.
Unscrew locking nuts.
Carefully remove secondary
ash pan and dispose of ash
into a metal container.
Emptying the Ash Pan
•
The boiler contains two areas where ash needs to be removed at regular intervals.
•
The primary ash pan is located in the main combustion chamber. The frequency of
emptying the ash pan is determined by the length of time the boiler has been running
and under what load conditions. Once the ash in the ash pan has reached the top then it
should be emptied. A daily check during the first few days of operation will give an
indication as to when it needs to be emptied.
ECOMPACT 15
Page 23
Boiler Operation & Maintenance
© Wood Energy Solutions
woodenergysolutions.ie