3200NT Timer
9
Timer Programming Mode
1.
Enter
3200NT
Programming Mode
Press and hold both the
Set Up
and
Set Down
buttons for
five (5) seconds to enter Programming Mode. When the
program mode is entered, the program light illuminates.
2.
Set Feed Water Hardness
The feed water hardness setting displays only if the
Regeneration Type is set to Meter Immediate or Meter
Delayed.
— Press the
Set Up
and
Set Down
buttons to set the
amount of feed water hardness (in grains/gallon). The
system automatically calculates treated water capacity
based on the feed water hardness and the system
capacity.
— Press the
Extra Cycle
button to proceed to the next
step.
3.
Set Regeneration Time
A non-flashing colon between two sets of numbers
identifies the
Regeneration Time
display. Set the desired
time of day that you want
Regeneration
to occur.
— Press the
Set Up
and
Set Down
buttons to adjust this
value.
— Press the
Extra Cycle
button to proceed to the next
step.
4.
Set Regeneration Day Override
Us this display to set the maximum amount of time (in
days) the unit can be
In Service
without a
Regeneration
.
— For System 4 Time Clock regeneration mode the
system regenerates at the time set in Step 4 after the
number of days programmed in this step.
— For all other System Types (4 Meter Immediate,
4 Meter Delayed, 5, 6, 7, 9) the system regenerates
after the number of days programmed in this step
unless the meter initiates a
Regeneration
cycle
earlier.
— Press the
Extra Cycle
button to proceed to the next
step.
Timer programming is complete and exits from the
Programming Mode. Normal operation resumes.