Hermes Operator Note Page 19 of 32
4.14
Transmission Power (AT S160)
The command enables the RF transmit power to be modified. Different RF
units have different capabilities and may change, depending on what is
supplied.
The SXn50 range of transceivers have 2 levels only. The levels for the 1W
and 2W versions of the G-MAX are shown in Table 7. Table 8 shows the 2
levels for the SXn50 range.
Power
Level
Output Power for 1W G-MAX
Output Power for 2W G-MAX
mW
(nominal)
dBm
(nominal)
Tolerance
(dB)
mW
(nominal)
dBm
(nominal)
Tolerance
(dB)
1
16
12
±3
31
15
±3
2
25
14
±3
50
17
±3
3
40
16
±3
79
19
±3
4
63
18
±1.5
126
21
±1.5
5
100
20
±1.5
200
23
±1.5
6
158
22
±1.5
316
25
±1.5
7
251
24
±1.5
500
27
±1.5
8
398
26
±1.5
794
29
±1.5
9
631
28
±1.5
1260
31
±1.5
10
1000
30
±1.5
2000
33
±1.5
Table 7 Power Levels for G-MAX Radios
Power